DKS 6002 Owner's Manual

DKS 6002 Owner's Manual

Residential vehicular swing gate actuators
Hide thumbs Also See for 6002:

Advertisement

Owner's Manual
P/N 6001-065 REV E, 5/04
Copyright 2003 DoorKing, Inc. All rights reserved.
Residential Vehicular Swing Gate Actuators
Model 6002
DoorKing, Inc.
120 Glasgow Avenue
Inglewood, California 90301
Phone: 310-645-0023
Fax: 310-641-1586
www.doorking.com
U.S.A.

Advertisement

Table of Contents
loading

Summary of Contents for DKS 6002

  • Page 1 Owner’s Manual Model 6002 Residential Vehicular Swing Gate Actuators DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 6001-065 REV E, 5/04 Copyright 2003 DoorKing, Inc. All rights reserved.
  • Page 2 Page 2...
  • Page 3 Use this manual with the following models only. Models 6002-080 with 4302-010 circuit board. DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions or changes.
  • Page 4 IMPORTANT NOTICES Vehicular gate systems provide convenience to their users and limit vehicular traffic onto your property. These systems can produce high levels of force; therefore it is important that you are aware of possible hazards associated with your gate operating system. These hazards may include pinch points, entrapment, absence of controlled pedestrian access or traffic backup.
  • Page 5: Gate Construction

    IMPORTANT SAFETY INSTRUCTIONS WARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3. Always keep people and objects away from gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.
  • Page 6 RESTRICTIONS AND WARNINGS Install The Gate Operator Only If: • The operator is appropriate for the usage Class of the application. • All exposed pinch points are eliminated or guarded. • This operator is intended for installation only on swing gates used to control vehicular traffic. Pedestrians must be provided with a separate access opening.
  • Page 7 ENTRAPMENT PROTECTION This vehicular gate operator is equipped with an inherent adjustable current sensing system (Type A). This system will sense an obstruction in both the opening and closing gate cycles, and will cause the gate to reverse direction should an obstruction be encountered. If the system detects a second obstruction before reaching the full open or close limit after the initial reversal, an alarm will activate and the operator will require a reset before resuming normal operation.
  • Page 8 GLOSSARY GATE – A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a stand-alone passage barrier or is that portion of a wall or fence system that controls entrance and/or egress by persons or vehicles and completes the perimeter of a defined area. RESIDENTIAL VEHICULAR GATE OPERATOR-CLASS I - A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or garage or parking area associated therewith.
  • Page 9: Table Of Contents

    TABLE OF CONTENTS Section 1 – Actuator Installation Specifications ............................11 Installation Dimensions ..........................12 Preliminary Checks...........................13 Actuator Installation ..........................14 Section 2 – Control Panel Installation and Wiring Typical Installation / Conduit Requirements .....................17 Control Box ..............................18 Actuator Wiring ............................19 Main Terminal Control Wiring ........................20 Main Terminal Description........................21 Secondary Entrapment Protection Device Wiring ..................22 Secondary Entrapment Device Terminal Description................23...
  • Page 10 Page 10...
  • Page 11: Section 1 - Actuator Installation

    SECTION 1 – ACTUATOR INSTALLATION Prior to beginning the installation of the swing gate actuator, we suggest that you become familiar with the instructions, illustrations, and wiring guide-lines in this manual. This will help insure that your installation is performed in an efficient and professional manner. The proper installation of the vehicular swing gate actuator is an extremely important and integral part of the overall access control system.
  • Page 12: Installation Dimensions

    Installation Dimensions OPEN TO THE INSIDE Gate Closed 90° For Gates up to 14 Feet 90° / Sec Rod Stroke 46.75 Note 1: MINIMUM Dimensions. Figure 2 OPEN TO THE OUTSIDE For Gates up to 14 Feet 90° / Sec Rod Stroke 46.75 Note 1: MINIMUM Dimensions.
  • Page 13: Preliminary Checks

    Preliminary Checks If the dimensions on the gate post or the position of the hinge do not allow Dimension A and/or B to be kept within the required value, make a recess in the gate post as shown in figure 4 to accommodate the rear bracket. The height of the recess should be a minimum of 8 inches.
  • Page 14: Actuator Installation

    Actuator Installation Install the rear bracket to the gate post according to the dimensions in 1.2. In the case of an iron post, weld the bracket directly onto the gate post. In the case of a brick / concrete column, flush- mount a steel wall plate (not supplied) and then weld the bracket to the plate.
  • Page 15 Do not block the holes on the bottom of the motor (fig. 10). Rotate the small electrical housing cover on the actuator so that the DKS logo is right side up (fig. 11). Permanently install the two supplied warning...
  • Page 16 Page 16...
  • Page 17: Section 2 - Control Panel Installation And Wiring

    2. Optional solar panel charging system. Control Panel. Junction box (not supplied). Lead-in wire(s) from loop(s). DOORKING, INC., INGLEWOOD, CA 90301 115 VAC Input power. Title: Model 6002 Actuator Typical Installation. Master / slave interface cable (not supplied). Date: 5/04 Dwg. No. M6001-065-1 Rev.
  • Page 18: Control Box

    .875 KO on hinge Transformer side of cabinet Housing 1.25 1.25 12.25 1.125 KO 1-Place .875 KO 4-Places 10.75 DOORKING, INC., INGLEWOOD, CA 90301 12.0 Model 6002/6400 Control Mounting Dimensions Title: Date: 5/04 Dwg. No. M6001-065-2 Rev. Figure 13 Page 18...
  • Page 19: Actuator Wiring

    Actuator Wiring Connect each actuator cable to the control panel as shown below. Be sure that wiring and connections are made in accordance with local electrical codes. MASTER Grn/Wht Common Green Slow Dwn Yellow Limit Slow Dwn Orange Limit Motor Blue Motor Brown...
  • Page 20: Main Terminal Control Wiring

    Main Terminal Control Wiring Controls must be far enough from the gate so that the user is prevented from coming in contact with the gate while operating the controls. Outdoor or easily accessible controls should have a security feature to prevent unauthorized use. •...
  • Page 21: Main Terminal Description

    Main Terminal Description 24V COMMON RADIO RELAY - SINGLE BUTTTON ACTIVATION INPUT When gate is closed, input will open gate. When gate is open and auto close timer is turned on, input will re-set and hold timer. When gate is open and auto close timer is turned off, input will close gate. When gate is closing, input will reverse gate.
  • Page 22: Secondary Entrapment Protection Device Wiring

    Secondary Entrapment Protection Device Wiring This swing gate operator uses an inherent entrapment sensing system (Type A) and has provisions for connection of secondary entrapment protection devices. External entrapment protection devices are required to insure a safe gate operating system. Secondary entrapment protection may be provided by a combination of non-contact (Type B1) sensors.
  • Page 23: Secondary Entrapment Device Terminal Description

    Secondary Entrapment Device Terminal Description 1. OPEN PHOTO-BEAM This input is only active when the gate is in the opening cycle. If the open photo-beam is activated during the opening cycle, the gate will stop. The gate will remain stopped until the photo-beam input is cleared, at which time the gate will resume the open cycle.
  • Page 24: Loop Detector And Loop Wiring

    Loop Detector and Loop Wiring • Loops and loop detectors are required to provide protection to vehicular traffic through the gate system. • Loop detector wiring is shown for DoorKing model 9405 and 9406 Plug-In loop detectors only. If other loop detectors are used, refer to the installation instructions supplied with those detectors for wiring requirements.
  • Page 25: Battery And Solar Panel Wiring

    Battery and Solar Panel Wiring Batteries are required for the actuators to operate properly. Two 12-Volt 3.4 amp hour batteries are provided with the actuator control panel. Batteries should be replaced every two years on average. When replacing batteries, be sure to connect them in series with each other: POSITIVE (+) to NEGATIVE (-).
  • Page 26 Page 26...
  • Page 27: Section 3 - Adjustments

    SECTION 3 – ADJUSTMENTS Control Board Adjustments The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is complete. Whenever any of the programming switches on the circuit board are changed, batteries and solar panels must be disconnected and main power must be shut- off.
  • Page 28: Switch Settings

    Switch Settings The two DIP-switches located on the circuit board are used to program the actuators to operate in various modes and to turn on or off various operating features. Whenever a switch setting is changed, batteries and solar panels must be disconnected and power must be turned OFF. After the switch settings are changed, turn power back on and then re-connect the batteries and solar panels for the new setting to take affect.
  • Page 29: Switch Descriptions And Functions

    Switch Descriptions and Functions SW1 Switch 1: Sets direction of the master actuator so that it cycles open upon initial power up and open command. If the actuator begins to cycle close upon initial power up and open command, turn power off and change the setting on this switch.
  • Page 30: Limit Switch Adjustment

    Limit Switch Adjustment The limit switches on this actuator are adjustable to allow you to control the travel of the gate and to precisely set the full open and full closed position of the gate. This feature is especially useful in applications where the gate opens only partially, such as on a curved driveway.
  • Page 31: Reverse Sensitivity Adjustment

    Reverse Sensitivity Adjustment This vehicular gate operator is equipped with an inherent adjustable reverse sensor (Type A) that is used as the primary entrapment sensing system. Upon sensing an obstruction in either the opening or closing gate cycle, the gate operator will reverse direction. For this system to function correctly, the gate must be properly installed and work freely in both directions.
  • Page 32 Page 32...
  • Page 33: Section 4 - Operating Instructions

    SECTION 4 – OPERATING INSTRUCTIONS Under various entrapment conditions the operator will assume either a soft or hard shutdown (alarm) condition. To determine what type of reset action is required, you will need to understand how the different entrapment conditions affect the gate operator. Soft Shutdown This occurs in various situations where the inherent or secondary entrapment protection devices have been activated.
  • Page 34: Hard Shutdown

    Inspect the gate and gate hardware. • NOTE: Models 6001 and 6002 operators have a built-in reset push button located on the bottom of the control box. Activating this button will return the gate operator to normal operation, but will not activate the gate operator.
  • Page 35: Manual Release

    Manual Release The gate can be operated manually in the event of a power failure or malfunction by removing the cover and inserting the release key. NOTE: Never attempt to manually operate any gate with an operator attached to it until you have verified that power to the operator has been shut-off.
  • Page 36 Page 36...
  • Page 37: Section 5 - Maintenance And Troubleshooting

    SECTION 5 – MAINTENANCE AND TROUBLESHOOTING Inspection and service of this gate operator by a qualified technician should be performed anytime a malfunction is observed or suspected. High cycle usage may require more frequent service checks. Maintenance Schedule When servicing the gate operator, always check any secondary (external) reversing devices (loops, photo eyes, etc.) for proper operation.
  • Page 38: Trouble Shooting

    Trouble Shooting Have a good VOM meter to check voltages and continuity. A Meg-Ohm meter capable of checking up to 500 meg-ohms of resistance is necessary to properly check the integrity of the ground loops. When a malfunction occurs, isolate the problem to one of three areas: 1) the operator, 2) the loop system, 3) the keying devices.
  • Page 39 • Disconnect the gate from the actuator and check that the gate swings freely without any Gate opens a short binding. distance, then • stops and reverses. Check the reverse sensitivity. • Check the secondary safety devices. • Replace the circuit board. •...
  • Page 40: Accessories

    Accessories The following accessory items are available for the model 6001 and 6002 swing gate operators. Photo Cell Non-contact (photo-cells) sensors for use as a secondary entrapment protection device. EMX Industries, Inc., Model IRB-325 MMTC, Inc., Model E3K-R10K4-NR Loop Detector Detectors plug directly into ports on circuit board simplifying wiring.
  • Page 41 Page 41...

Table of Contents