  • Page 1 Gate Operator and 6004 6004 6004 Control Box Mounting Vehicular Swing Gate Operator To wire this operator and complete the installation, refer to a specific control box “Wiring/Owner’s manual”. 6004-065-E-5-12 D O O R K I N G Copyright 2012 DoorKing, Inc. All rights reserved.
  • Page 3: Specifications

    6004 SPECIFICATIONS Class of Operation Model 6004 - UL 325 Class I Type of Gate Vehicular Swing Gates Only Gate Operator Voltage 24 VDC Current 3 Amps Motor Torque 300 Nm Max Gate Weight 300 Lbs. Max Gate Length 8 Feet...
  • Page 4: Table Of Contents

    TABLE OF CONTENTS SPECIFICATIONS 6004 Specifications ASTM F2200 Standard for Gate Construction Important Safety Instructions Instructions regarding intended installation: Important Notices UL 325 Entrapment Protection Glossary Swing Gate Requirements Swing Gate Protection INSTALLATION Sample Installation Operator Description and Disassembly Operator Mounting Positions Mounting Bracket and Gate Attachment Bracket Operator Layouts “Gate Opens to the Inside”...
  • Page 5: Astm F2200 Standard For Gate Construction

    2. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving in the opening direction. 3. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exist, such as the perimeter reachable by a moving gate or barrier. 6004-065-E-5-12...
  • Page 6: Important Notices

    Do not allow children to play in the area of the operator or to play with any gate-operating device. • To remove the gate operator from service, operate the gate to the full open position and then shut off power to the operator at the service panel. 6004-065-E-5-12...
  • Page 7: Ul 325 Entrapment Protection

    C - Inherent adjustable clutch or pressure relief device. D - Provision for connection of, or supplied with, an actuating device requiring continuous pressure to maintain opening or closing motion of the gate. E - An inherent audio alarm. 6004-065-E-5-12...
  • Page 8: Glossary

    ENTRAPMENT - The condition when an object is caught or held in a position that increases the risk of injury. 6004-065-E-5-12...
  • Page 9: Swing Gate Requirements

    NOT required for this area. If distance is less than 16 inches, entrapment protection in this area is required. ASTM F2200 7.1.1.2 Not Allowed Gates shall have smooth bottom edges, with vertical bottom edged protrusions not exceeding 0.50 inches. ASTM F2200 4.3 6004-065-E-5-12...
  • Page 10: Swing Gate Protection

    Located so pedestrians cannot come in contact with the vehicular gate. Automatic Exit Loop (Optional) will provide an open command to the gate operator(s) when a vehicle is exiting the property. See page 15 for typical loop layout locations. 6004-065-E-5-12...
  • Page 11: Installation

    Hinge Placement Note: It’s important to consider hinge placement on a pilaster or a thick wall when installing the gate. Placing hinges close to the corner can eliminate a potential entrapment area (See Swing Gate Requirements on page 7). 6004-065-E-5-12...
  • Page 12: Operator Description And Disassembly

    Note: Lock and unlock directions Operator Circuit Board Wiring will be reversed when motor is in l t ( the right-side orientation. Lockpin Arm Assembly Lockpin Gate Retaining Ring Attachment Bracket Spacing Washers Note: Operator hardware is metric. Retaining Ring 6004-065-E-5-12...
  • Page 13: Operator Mounting Positions

    Mounting Bracket shown in Left-Side Opening Position. 1 5/8” Attach mounting bracket to pilaster or wall with four (4) #10 Weld gate attachment bracket to gate or screws and suitable expansion hardware (Not supplied). use two (2) suitable screws (Not supplied). 6004-065-E-5-12...
  • Page 14: Operator Layouts "Gate Opens To The Inside" Or "Gate Opens To The Outside

    C max. Gate Attachment Bracket 2.50 - 4.25 4.25 - 5.00 17.00 4.25 - 6.25 4.25 - 5.00 15.00 6.25 - 8.25 4.25 - 5.00 13.00 8.25 - 10.25 4.25 - 5.00 11.00 10.25 - 12.25 4.25 - 5.00 9.50 6004-065-E-5-12...
  • Page 15: Mounting 115 Vac Or Solar Control Box With Conduit

    D O O R K I N G Secondary Operator Junction Primary Interconnection Cable 30 feet. P/N 2600-755 Cable Operator Interconnection Cable 40 feet. P/N 2600-756 Cable Interconnection Cable 50 feet. P/N 2600-757 DoorKing interconnection cable (Sold separately) inside underground conduit 6004-065-E-5-12...
  • Page 16 Typical conduit To attach post to concrete, configuration DoorKing recommends four (4) 3/8” x 3” sleeve anchors (not supplied). (not supplied). Do Not mount post on asphalt. 6004-065-E-5-12...
  • Page 17: Install Warning Signs

    They will reverse the cycling of the gate gate. Reverse loops work in conjunction with while a vehicle is in or near the gate’s completely opened by the time the shadow loop and both should be used. swing pathway. you drive up to it (Free exit). 6004-065-E-5-12...
  • Page 18: Photo Sensor Positions "Opens To The Inside

    Secondary Entrapment Protection Device: In addition to the inherent reversing sensor system, the Model 6004 has a 6-pin UL 325 terminal for the connection of photo sensors-Type B1 secondary entrapment protection device required by UL 325 standards (see 115 VAC or Solar control box wiring/owner’s manual). Entrapment protection devices must be installed to reduce the risk of injury.
  • Page 19: Accessory Items

    Accessory Items The following accessory items are available for the model 6004 swing gate operator. Control Box Types - Fully controls actuator arm(s) with built-in battery back-up system. P/N 4302-111 - 115 VAC Standard Control Box, 115 VAC 60 Hz Input to box, 24 VDC output to gate operator.
  • Page 20 6004 Primary/Secondary 4302 Circuit Board Connection Primary Operator Secondary Operator D O O R K I N G D O O R K I N G Operator Cable Operator Cable Brown 1 Blue 2 Orange 3 Red 4 Yellow 5...
  • Page 21 6004-065-E-5-12...
  • Page 22: 6004-065

    Gate Operator and 6004 6004 6004 Control Box Mounting Vehicular Swing Gate Operator To wire this operator and complete the installation, refer to the specific control box “Wiring/Owner’s manual”. 6004-065-E-5-12 www.doorking.com DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A.