Connecting The Connection Contact For Wall Box And Window Switch (Multi-Function Contact) - Berbel BEH 90 FL Installation Instructions Manual

Built-in hoods
Table of Contents

Advertisement

Push the front panel to the desired position.
Make sure that the front panel is in the correct
position.
Push the stops forwards up to the front panel.
Tighten the screws.
Connecting the connection contact for
wall box and window switch (multi-
function contact)
DANGER
Fatal electric shock due to improper
connection.
Only have work on the voltage
supply carried out by a qualified,
trained specialist electrician under
consideration of the country-specific
regulations and standards (in
Germany e.g.
DIN 57100/VDE 0100, Part 701).
Have the following steps carried out by a
specialist electrician only.
A window switch and a berbel wall box (e.g. BMK-F)
can be connected to the device. The cable
terminals for this are mounted on the device's fan
housing.
Connection schematic for the multi-function contact
and the wall box contact
ATTENTION
Damage to the electronics if the
polarity of the control cable is incorrect.
Make sure that the polarity of the
control cable is correct.
Only connect wire 1 to terminal 1
and wire 2 to terminal 2.
2
1
Terminal for the multi-function contact (F-K)
Terminal for the wall box (BMK)
Control cable
Power supply unit
Wall box BMK-F
Actuation contact, potential-free
Control box for the berbel extractor hood
Connection terminal for the wall box
The connection terminal for the wall box
automatically controls the remotely controlled wall
box BMK.
Installing the device
4
3
5
6
7
27