  • Page 1 BEH Glassline Built-in hood Operating and installation instructions for the model: BEH 60 GL / BEH 90 GL 12/2013 (updated 01/2014) Translation of the original German instructions...
  • Page 2 In the following text, the products from our product representations for ease of presentation. line berbel Built-in hood BEH GL will be referred to in short as the device. If elements are referred to in the text or in the legends,...
  • Page 3: Table Of Contents

    Contents Safety ..................................5 Proper and intended use ............................5 Ban on independent conversions and modifications ....................5 Layout of hazard notices.............................5 Layout of notices regarding damage to property or the environment.................5 General safety instructions............................6 Basic safety instructions .............................6 Safety instructions for the user..........................6 Safety instructions for the installer...........................8 Operating instructions ............................10 Description for the user............................10...
  • Page 4 Cleaning the surfaces ...............................60 Cleaning the controls ..............................60 Disassembling the device .............................60 Disposal ................................62 Disposal of the packaging............................62 Disposal ..................................62 Technical specifications ............................63 Ratings plate (type label) ............................63 Built-in hood BEH 60 GL............................63 Contact.................................64 Contacting the customer services of the manufacturer ....................64...
  • Page 5: Safety

    Conversions or Specific, important safety instructions can be found: modifications without the approval of berbel - in the "Safety instructions for the installer" for Ablufttechnik GmbH are not permitted. persons installing or removing the device.
  • Page 6: General Safety Instructions

    In the event of damage, contact your If fluid does enter the device: dealer or berbel customer service. You may only - Immediately shut off the power supply use the device if it is in perfect working order.
  • Page 7 Safety instructions for the user Avoiding risks of injury In recirculated air mode: § To prevent the risk of falling, use a stable step- § A covered or sealed ventilation outlet can cause a ladder for all work on the device, for example fire hazard.
  • Page 8: Safety Instructions For The Installer

    Ø Check the device and all its parts for visible damage. the mains supply in the event of an emergency. If In the event of damage, contact your dealer or berbel the mains plug is inaccessible following installation, customer service. You may only install the device if it an all-pole isolating device with a contact gap of at is in perfect working order.
  • Page 9 Safety instructions for the installer In recirculated air mode: properly (e.g. the under-pressure monitor P4 checked in accordance with DVGW-VP121 and in § A covered or sealed ventilation outlet can cause a accordance with DIN 18841:2005-12 TÜV). fire hazard. In the case of recirculated air devices, out flowing air must be able to escape back into the §...
  • Page 10: Operating Instructions

    Operating instructions Operating instructions Description for the user The following illustrations show the way the possible operating modes work. The devices used are shown as symbols. The illustrations are meant to serve as a guide. The device displayed may differ in shape from your device.
  • Page 11: Device View With Closed Lower Section

    Description for the user Device view with closed lower section Built-in hood BEH 60 GL Lower section   Extractor Front panel with EcoSwitch control panel   Illumination  Operating instructions...
  • Page 12: Device View With Opened Lower Section

    Description for the user Device view with opened lower section Built-in hood BEH 60 GL Capillary trap   Upper section Lower section   Front panel with EcoSwitch control panel   Operating instructions...
  • Page 13: Operating

    Operating Ø To activate the desired function, touch the respective Operating area with your finger. WARNING Suffocation risk due to low oxygen levels when operating the device. Ø Ensure there is an adequate supply of fresh air into the dwelling. Ø...
  • Page 14: Turning On The Device

    Operating The numbers in circles in the following To turn the device on, proceed as follows: descriptions refer to the diagram shown Ø Briefly touch the touch pad "ON/OFF".  previously. Example: "Touch pad " describes the touch pad for ...
  • Page 15: Turning Off The Device

    Operating Turning off the device The device is switched on, the control symbols of the active functions are dimly lit. Further function can be If the automatic run-on function is turned off: switched on. You turn the device off by pressing touch pad "ON/OFF".
  • Page 16: Turning On The Ventilation Function

    Operating Turning on the ventilation function ATTENTION WARNING Risk of fire due to flambéing or overheated oil and fat under the Explosion risk and fire hazard from gas device. or explosive or flammable gas mixtures in the kitchen when operating electrical Naked flames can cause damage to equipment.
  • Page 17: Changing The Power Level

    Operating To remove cooking vapours best: Example: You want to turn on power level 4 (i.e. maximum fan power). Ø Turn the device on when you start cooking. Ø Briefly touch the touch pad for power level 4.  Ø If you are frying, turn the device to its highest power setting.
  • Page 18: Turning Off The Ventilation Function

    Operating Turning off the ventilation function Turning on the run-on function Ø To turn off the ventilation function, briefly touch the Manually turning on the run-on function touch pad "ON/OFF".  The device comes with a run-on function. If you use this function, the device will work for a further ten minutes at the last chosen power level.
  • Page 19: Turning Off The Run-On Function

    Operating Turning off the run-on function Turning the hob lighting on/off Ø To turn off the run-on function while it is operating, The device is fitted with an energy saving LED light for briefly touch the touch pad lighting up the hob. ...
  • Page 20: Using The Extraction Mode/Recirculated Air Mode Selection

    This function can only be used: Ø after the function has been activated in configuration mode and Ø when used in conjunction with a berbel BMK F wall box and a BHF hybrid filter. You can choose between the extraction mode and recirculated air mode at any time.
  • Page 21: Control Indicators

    Operating Control indicators Making settings in the configuration mode The control indicators on the control panel remind you You can adjust the following basic settings in the to perform certain maintenance tasks. configuration mode: § Activate control indicator  "Effect lighting" (with ...
  • Page 22 Operating In order to turn the extraction mode/recirculated air mode switching function on, proceed as follows: Ø Turn the configuration mode on. Ø Briefly touch the touch pad (power level 2).  All the operating symbols light up brightly for five seconds.
  • Page 23 Operating Flashing control indicator: resetting the "change the Setting: turning on the automatic run-on function recirculated air filter/filling" As delivered, the automatic run-on function is turned In recirculated air mode, you must change the filter off. filling after at most 350 hours of operation. After this If you turn on the automatic run-on function, the device amount of operating hours, the "change the will continue to operate after it has been turned off for a...
  • Page 24: Using The Extension

    Using the extension Using the extension Retracting the extension The device has an extension. With the extension To retract the extension, proceed as follows: opened, the size of the device's capture area Ø Press the extension on the front panel rearwards into increases.
  • Page 25: Cleaning

    Cleaning Cleaning with normal soiling Cleaning The device is designed to capture foreign particles from the room air that is sucked in and to collect them DANGER in grease trays (upper and lower sections). If the device is normally soiled, you must remove the lower Fatal electrical shocks through liquids section.
  • Page 26: Cleaning The Controls

    Cleaning Close the lower section. Ø Use a soft, damp cloth for cleaning. Ø Close the lower section by pushing it upwards until Ø Wipe off the parts. the two magnetic fasteners can be heard to click Ø Grasp the lower section on its sides with both hands together.
  • Page 27 Cleaning Remove the capillary trap Insert the capillary trap Ø Grasp the capillary trap on its sides with both hands. Ø Make sure that the capillary trap is completely dry before re-inserting. Ø Pull the capillary trap downwards (1). Ø Ensure that the words "Front" on the capillary trap Ø...
  • Page 28: Cleaning The Surfaces

    Cleaning Cleaning the surfaces Ø Press the lower section rearwards into the device (1.). ATTENTION Ø Pull the lower section downwards (2.) until it clicks into place. Damage to the surfaces from sharp Ø Make sure that the lower section is fitted correctly. objects or abrasive cleaning agents.
  • Page 29: Maintenance

    The device is fitted with maintenance-free LED lighting. The bulbs have a service life of approximately 30,000 ATTENTION operating hours. Ø If you have any problems, contact your berbel dealer Damage caused by falling parts. or customer services. Ø Protect areas and devices (e.g.
  • Page 30 Maintenance Remove the hybrid filter Remove the recirculation filter To change the filter filling, proceed as follows: To change the filter filling, proceed as follows: Ø Remove the exhaust pipe from the socket. Ø Lift the filter at least 3 cm (1.). Ø...
  • Page 31 Maintenance Insert the filter Valid for all filters: To make sure that the filters are installed The filter is inserted correctly when the bottom edge of correctly, a guide is installed on the filter the filter is parallel to the top edge of the fan's housing seating.
  • Page 32: Troubleshooting

    The device is connected to a window Open the window. contact switch and the window is closed. The device is connected to a berbel P4 Open the window. Multi under-pressure monitor and the Wait until the air pressure returns to under-pressure monitor has detected a normal.
  • Page 33 See Changing the filter filling (hybrid and recirculated air filters) on page 29. The exhaust pipe was not properly Please consult your berbel dealer or berbel connected or installed. customer services. Ø If the fault persists, please contact your berbel dealer or berbel customer services.
  • Page 34: Installation Instructions

    Description for the installer Installation instructions Ø Make sure that the cross-section of the ventilation slits in the top structure is more than 300 cm². Description for the installer Ø Make sure that the air can flow freely out of the device.
  • Page 35: Information About Extracted Air Mode

    Ø Make sure that the air can flow freely out of the device. § Only operated the device with a window contact switch connected or the berbel P4 Multi under- Ø Ensure that you can change the filter filling at a later pressure monitor.
  • Page 36 Description for the installer § The exhaust hose is as direct and short as possible. WARNING § The room air to be extracted is able to flow freely through the exhaust pipe without turbulence and Suffocation risk due to low oxygen back pressure.
  • Page 37 Only use tubes with a smooth surface on the inside. pipe is not less than the diameter of the fan outlet. Such pipes have a low air resistance. Ø Use berbel pipes, bends and the optimal berbel BMK wall box, for example. Avoid the installation of: §...
  • Page 38 Description for the installer If you run the exhaust pipe out through the roof, you Ø Make sure that the connection to the chimney is via a must ensure that: 90° bend which points upwards. § The pipe diameter of the fan outlet is not larger than the diameter of the roof feedthrough.
  • Page 39: Basics About The Device

    Basics about the device § The slats of the wall box's louvred cover do not engage automatically and hold the device when the hang straight down. final position has been reached. § There is no insect screen fitted in the wall box. Insect screens do not lead to complete impairment of the diameter of the exhaust pipe.
  • Page 40: Device View From Above

    Basics about the device Device view from above Built-in hood BEH 60 GL Mains plug   Contacts for the window switch (multi-function Right bracket   contact) and BMK wall box Fan outlet (Ø 150 mm) with guides for filter and Left bracket ...
  • Page 41: Device View From Underneath With A Closed Lower Section

    Basics about the device Device view from underneath with a closed lower section Built-in hood BEH 60 GL Lower section   Extractor EcoSwitch operating panel   Illumination  Installation instructions...
  • Page 42: Device View With Opened Lower Section

    Basics about the device Device view with opened lower section Built-in hood BEH 60 GL Capillary trap   Upper section Lower section   Front panel   Installation instructions...
  • Page 43: Preparation For Installation

    Preparation for installation Qualifications of personnel Preparation for installation Two persons are required to mechanically install the In this chapter you will learn what the prerequisites are device. for installation. Perform all the steps in this guide one after the other. These technicians must have sufficient craftsman skills and knowledge.
  • Page 44: Brief Overview Of The Installation

    P4 Multi under-pressure monitor and a § When in recirculated air or hybrid mode: berbel wall box (e.g. BMK F). The cable clamps for this insert the filter. are attached to the fan housing of the device. The §...
  • Page 45: Tools And Equipment Needed

    Preparation for installation Tools and equipment needed ATTENTION For installation you need the following tools, materials and documents: Scratched surfaces from metallic, sharp-edged objects, e.g. belt buckles or tools during transport. Ø Transport the device without any contact to objects that could scratch the device.
  • Page 46: Check The Delivery

    Ø Check the delivered parts for damage. Ø If any parts are damaged or missing, contact your berbel dealer or customer services. Built-in hood BEH 60 GL scope of delivery Only for hybrid mode:  Hybrid filter BHF 150 + Only for recirculated air mode: ...
  • Page 47 Remove the parts for installation Remove the lower section Ø Remove the lower section. Ø Open the lower section by pulling the flap on the rounded edge downwards. Ø Grasp the folded down lower section at the sides with both hands. Remove the capillary trap Ø...
  • Page 48: Installing The Device

    Installing the device Installing the device Create the installation cut-out The installation cut-out must have the following WARNING dimensions: Risk of injury from falling parts. Ø Ensure that no-one is below the working area during the work. WARNING Risk of injury from falling parts if improperly Description Size fastened.
  • Page 49: Safety Distances Are Observed

    Installing the device Safety distances are observed Install the brackets The following illustrations show the way the For this work-step you need a large Phillips possible operating modes work. The devices screwdriver. used are shown as symbols. The illustrations The brackets provided on delivery are screwed onto are meant to serve as a guide.
  • Page 50: Hang The Device

    Installing the device Align the device horizontally Hang the device For this step you do not require any tools. DANGER You can slightly adjust the alignment of the device. Danger from falling parts if improperly Proceed as follows: fastened. Ø Push the device into the desired position by pushing Ø...
  • Page 51: Setting The End Stop For The Depth Adjustment

    Installing the device Setting the end stop for the depth adjustment Ø Ensure that the front panel is in the correct position. For this work-step, you need a SW7 (M4) spanner. Ø Tighten up the M4 hex bolts again (3.). You can set the position of the front panel when it has been pushed in.
  • Page 52: Connect The Connection Cables For The Wall Box, P4 Multi And Window Contact Switch

     switch, or a berbel P4 Multi under-pressure monitor Control cable  and a berbel wall box (e.g. BMK F). The cable clamps Power supply unit  for this are attached to the fan housing of the device. Wall box BMK F ...
  • Page 53 For this step you need a small cross-head screwdriver for the terminals in the berbel extractor hood. Ø Lay the control cable from the wall box to the extractor hood.
  • Page 54 The following step describes how the window contact The control cable needs to be laid from the berbel P4 switch is connected. Multi under-pressure monitor to the connection...
  • Page 55: Creating The Exhaust Air Connection

    Installing the device Ø Open the screw of the "Fensterschalter" terminal 1. Ø Tighten the screw of terminal 1. Ø Take the wire 1 of the control cable. Ø Connect the cable wire 2 in the same way to the "Fensterschalter"...
  • Page 56 Installing the device Installing the device for extracted air mode CAUTION WARNING Risk of injury from falling parts. Risk of falling during work carried out Ø Ensure that no-one is underneath at height. the device while working. Ø Use a stable step-ladder. ATTENTION CAUTION Damage caused by falling parts.
  • Page 57 Installing the device Ø Push the exhaust pipe firmly into place on the guide Installing the device for hybrid mode on the fan. WARNING Risk of falling when changing the filter. Ø Use a stable step-ladder. CAUTION Risk of injury from falling parts. Ø...
  • Page 58: Install The Other Parts

    Installing the device Install the other parts Ø Seat the filter from above onto the guides in the fan housing. After installation, fit the removed parts as follows: Insert the capillary trap Ø Make sure that the capillary trap is completely dry before re-inserting.
  • Page 59: Connect The Power Supply

    Installing the device Replacing the lower section and closing it Close the lower section. Ø Grip the lower section with both hands. Ø Close the lower section by pushing it upwards until the two magnetic fasteners can be heard to click Ø...
  • Page 60: Initial Cleaning

    (e.g. in Germany DIN 57100 / VDE 0100, part 701). The berbel hood is installed and ready for use. WARNING Risk of falling when changing the filter. Initial cleaning Ø Use a stable step-ladder.
  • Page 61 Disassembling the device Only for hybrid and extracted air mode: Ø Remove the exhaust pipe. Only for hybrid and recirculated air mode: Ø Remove the filter. Ø Open the lower section. ATTENTION Damage caused by falling parts. Ø Protect areas and devices (e.g. cooled cooking hob) underneath the working area against damage, e.g.
  • Page 62: Disposal

    Disposal Ø Dispose of the packaging, separated into material Disposal groups, in an environmentally friendly way. Disposal of the packaging Disposal DANGER Danger of suffocation from packaging components (e.g. foils and polystyrene). Ø Store the film or other parts of the packaging in a location which is inaccessible to children.
  • Page 63: Technical Specifications

    Technical specifications Technical specifications Built-in hood BEH 60 GL Ratings plate (type label) BEH 60 GL The ratings plate is found inside the device behind the lower section. Width 600 mm Height Min. 405 to 635 mm* The following information is found on the ratings plate: Max.
  • Page 64: Contact