SECTION 4
APPLIANCES & SYSTEMS
LP Gas Level
Press and hold the "Levels Test" switch to
show approximate LP tank level.
The LP level is registered by a sending unit on
the tank. The gauge mounted on the side of the
tank will give a more accurate indication of
actual tank level if needed.
Battery Charge Meter
Push the "Levels Test" button to check the
level of charge (voltage) in the 12-volt coach
battery. The colored segments (red, yellow and
green) will light from the bottom up to the
amount of charge the battery contains.
Green - good or adequate charge.
Yellow - marginal charge.
Red - battery needs charging before use.
To get an accurate reading;
1. Both the chassis engine and the auxiliary
generator engine must be shut off and 110 Vac
shoreline unplugged.
2. An interior light should be turned on to
provide a small load which draws off the
battery surface charge.
Water Pump Switch
When use of the self-contained water system
is desired, turn the "Water Pump" switch on. The
"Pump On" light will illuminate when the pump
switch is on and the system is operable. Water
will be available as soon as a faucet is opened.
Refer to "Water Pump" for additional
information on the water pump and initial start-
up. (There is also a pump switch in the utility
compartment on the outside of the coach.)
4-4

LP GAS FURNACE

To Start Up:
1. Open the LP gas tank valve by turning fully
counterclockwise.
2. Move thermostat switch from OFF to HEAT
and press the Temp Selector button (Up/Down
arrows) until the desired temperature is shown
on the display.
3. Furnace fan will start to blow soon after
setting thermostat.
4. After about 30 seconds, the furnace burner
will light.
5. The furnace will now cycle off and on
automatically as the thermostat demands just
like a household furnace.
NOTE: If heat does not come out of the heat
ducts after a minute or so the burner is
not lit. Turn thermostat off for 3-5
minutes, check to be sure tank valve is
open and tank is not out of fuel, then try
steps 2-4 again. If it still will not light
after three attempts, go to Shut Down
steps and contact your dealer or a local
RV service center.
To Shut Down:
1. Slide thermostat switch to OFF position.
2. Close LP tank valve.
NOTE: Metal coatings used during manufacture
of the furnace burner parts may smoke
when the furnace is used for the first
time, which may also set off your smoke
alarm. If this happens, provide adequate