Winterization Valve
(See Water Drain Valve Location chart)
Turn the diverter valve handle so that it points
toward the suction tube.
Turn the water pump switch on.
Open each hot and cold water faucet handle in
the coach one at a time until antifreeze
solution just begins to flow from the faucet,
then close.
When Done Adding RV Antifreeze:
Turn water pump switch off.
Turn the diverter valve handle so it points
toward the water line to the pump as shown in
the photo. This will stop the flow from the
suction tube and revert the tank line flow to
the pump.
Replace the protective cap onto the end of the
suction tube to keep out insects and debris
when not in use.
Dump and Clean Holding Tanks:
Completely drain the sewage and waste water
holding tanks at an approved waste disposal
site. Drain the sewage tank first so the
following waste water can rinse any waste
solids from the dump outlet and sewer hose.
Close dump valves and refit the dust cap onto
the drain outlet.
Final Steps for "Blow-out" or
"Water System Antifreeze"
Siphon
Procedure
Tube
1. Close all drain valves and faucets to avoid
(insert into
container of
RV water
system
antifreeze)
2. Pour about one cup of non-toxic RV antifreeze
Winterizing
Valve
(point toward
siphon tube
NOTE: It is not necessary to add antifreeze to
for
winterizing)
3. Place a bucket beneath the sewage drain valve
4. Empty the water pump strainer filter bowl to
now totally winterized.
contamination by dirt or insects. Reinstall
water heater drain plug and close P-T relief
valve.
into the kitchen sink drain, bathroom sink
drain and shower drain. This prevents any
holding tank odors from entering the coach
during storage.
the toilet since the flush valve will be
closed.
Do not add automotive antifreeze or
caustic chemicals such as bleach or
laundry detergents into the toilet bowl or
holding tanks. Although these products
may have a deodorizing effect, they may
damage plastic and rubber parts in the
system.
outlet and re-drain the sewage and waste
holding tanks of any clean water that may
have entered during the "blow-out"
procedure.
Close dump valves to prevent valve shafts
from rusting and to prevent entry by rodents
and insects. Refit the dust cap onto the drain
outlet.
avoid water freezing and cracking the filter
bowl. Strainer is shown previously in this
section.
Your drainage and fresh water systems are