Winterizing Procedure - Winnebago Cambria Owner's Manual

Hide thumbs Also See for Cambria:
Table of Contents

Advertisement

Bypass Valve Close Up
(Model 23D shown)

WINTERIZING PROCEDURE

Blow Out Procedure
1. Level the motor home and drain the entire
plumbing system as described in the
following steps.
2. Open water line drain valves and drain fresh
water tank. (See Water System Drain Valve
Locations chart for locations of drain valves
on your model.)
3. Open the Exterior Wash Station shower knobs
and lay shower head on ground to drain any
water left in the shower line. Also place the tip
of your finger into the city water inlet and
gently press the backflow valve "button" in
the center of the inlet to drain any water
trapped in the inlet line.
4. Turn on water pump and open all sink faucets
and shower head knobs. Leave open after
water stops flowing.
5. Press the toilet flush pedal and hold until
water stops flowing in the toilet. Then turn
water pump switch off.
6. Turn off the water heater power switch before
draining the water heater tank to avoid
damage to the heating element. Drain the
water heater by removing the plug from the
base of the water heater tank, accessible from
the outside of the coach. (Requires socket and
ratchet.)
Also open the Pressure-Temperature relief
valve at the top right portion of the tank to
prevent air locking in the tank while draining.
Lift handle only when water heater is cold
7. After water has stopped draining at all faucets
and drain valves, leave faucets open and
connect a "blow-out" plug to the city water
connection on the coach. Then use a
compressed air hose regulated to 30 psi or less
to force air through the system. (A "blow-out"
plug can be purchased at any Winnebago or
Itasca dealer. P/N 701705-01-000.)