Troubleshooting - EIP CD425 Owner's Manual

Hide thumbs Also See for CD425:
Table of Contents

Advertisement

S
YMPTOM
Little or no airflow
Little or no water
extraction
Little or no defrost
when required
Unit vibrates
excessively
Water flooding inside
machine

TROUBLESHOOTING

C
AUSE
1. Loose fan on shaft
2. Fan motor burnt out
3. Dirty refrigeration coils
4. Loose electrical wiring
5. Fuse blown
1. Insufficient air flow
2. Compressor fault
3. Loss of refrigerant gas
1. Faulty Timer
2. Faulty bypass valve
1. Loose compressor
mounts
2. Damaged fan
1. Drain pipe blocked/frozen
2. Drain pipe too high
Page 10 of 13
Drawing : - TPC127A
Issue
: - 2
Date
: - 28/05/12
R
EMEDY
1. Tighten fan
2. Replace the fan motor
3. See Routine Maintenance
Section
4. Check the wiring diagram
to find fault and repair
5. Replace the fuse or reset
the circuit breaker
1. Check all of the above
2. Contact the Factory
Service Center
3. Contact the Factory
Service Center
1. Contact the Factory
Service Center
2. Contact the Factory
Service Center
1. Tighten nuts on
compressor mounts
2. Replace with a new fan
1. Clear the obstruction
2. Lower section of pipe