Should an electrical component fail, consult the Factory Service Center
to obtain the proper replacement part.
I
F ANY OF THE PRECEDING PROBLEMS OCCUR
I
P
NDUSTRIAL
OPERATION OF THE UNIT TO PREVENT PERMANENT DAMAGE
S
YMPTOM
Little or no
dehumidification
capacity
Dehumidifier does
not start
Rotor does not
rotate
No Dry or Wet Air
Airflow
Noisy
L
S
RODUCTS
TD
ERVICE

TROUBLESHOOTING

C
AUSE
Filter clogged
No regeneration heat
Reduced airflow
No rotation of Rotor
Air leakage
No power
Correct switch setting
Loose electrical wiring
Drive belt slipping
Drive belt broken
Rotor jammed
Drive motor faulty
Filter clogged
Fan faulty
Ducts blocked
Fan loose
Loose fastenings
Drawing : TPC465
Issue
Date
,
CONTACT THE
C
ENTER PRIOR TO CONTINUED
R
Clean or replace filters
Check Heaters / OHP
Check fans / duct
Check belt tension / drive motor
Check sealing
Check fuse
Check Auto / Manual switch
Check wiring diagram - fault
find & repair
Check belt tension
Replace drive belt
Check centre shaft, rim of rotor
Check supply /Replace motor
Clean or replace filters
Check supply / fan
Check duct for obstruction
Check fans secured firmly
Tighten all fastenings