Troubleshooting - EIP CD100 Owner's Manual

Advertisement

S
YMPTOM
Little or no airflow
Little or no water
extraction
Little or no defrost
when required
Unit vibrates
excessively
Water flooding inside
machine

TROUBLESHOOTING

C
1. Loose fan on shaft
2. Fan motor burnt out
3. Dirty refrigeration coils
4. Loose electrical wiring
1. Insufficient air flow
2. Compressor fault
3. Loss of refrigerant gas
1. Faulty Timer
2. Faulty bypass timer
1. Loose compressor
mounts
2. Damaged fan
1. Faulty water pump
2. Sticking float switch
3. Drain tray blocked
Spare parts available online
www.EIPLDIRECT.com
Page 9 of 12
AUSE
1. Tighten fan
2. Replace the fan motor
3. See Routine Maintenance
Section
4. Check the wiring diagram
to find fault and repair
1. Check all of the above
2. Contact the Factory
Service Center
3. Contact the Factory
Service Center
1. Contact the Factory
Service Center
2. Contact the Factory
Service Center
1. Tighten nuts on
compressor mounts
2. Replace with a new fan
1. Replace water pump
2. Remove obstruction
3. Remove obstruction
Drawing : - TPC385
Issue
: - 4
Date
: - 24/11/16
R
EMEDY