Troubleshooting - EIP CD85 Owner's Manual

Industrial dehumidifier
Table of Contents

Advertisement

S
YMPTOM
Unit inoperative
Little or no airflow
Little or no water
extraction
Little or no defrost
when required
Unit vibrates
excessively
Water flooding inside
the machine

TROUBLESHOOTING

C
AUSE
1. No power to unit
1. Fan motor burnt out
2. Dirty refrigeration coils
3. Loose electrical wiring
Fuse blown or circuit
breaker tripped
1. Insufficient air flow
2. Compressor fault
3. Loss of refrigerant gas
1. Faulty timer
2. Faulty by-pass valve
1. Loose compressor
2. Damaged fan
1. Drain pipe blocked/frozen
2. Drain pipe too high
3. Crimped or blocked tubing
Page 10 of 15
Drawing : - TPC361
Issue
: - 1
Date
: - 21/06/11
R
EMEDY
1. Check the power from
power supply panel
1. Replace the fan motor
2. See Routine Maintenance
Section
3. Check the wiring diagram
to find fault and repair
4. Replace the fuse or reset
the circuit breaker
1. Check all of the above
2. Contact the Factory
Service Center
3. Contact the Factory
Service Center
1. Contact the Factory
Service Center
2. Contact the Factory
Service Center
1. Tighten the nuts on the
compressor mounts
2. Replace fan
1. Clear the obstruction
2. Ensure that no section of
the drain hose is 1M max.
above the level of the water
outlet
3. Straighten, clear, or replace
tubing