5.2

ACCESS AND PARAMETER MODIFICATION

The two options referred to above - Set and Cloc – are used for accessing and modifying:
1. Appliance parameters, Set.
2. Date and Time parameters, Cloc.
The following basic procedure applies to both options.
Step
Button
1
2
3
-
4
5
1 - 4
fig. 26 – Set parameters. Hold down the Start/Stop button to access the parameters. Parameter -1 sets to the dose dispensed by peristaltic pump P1.
Use the Selection buttons to modify the parameter. Use the Functions button to move to another parameter. Confirm changes using the Start/Stop
User Manual
Action
Start/Stop – hold down to access the option required.
To access the Set parameters, hold down until the "Set" option appears on the display.
To access the Cloc (date and time setting) parameters, hold down until the "Cloc"
option appears on the display.
Functions - Selection of the parameter required (see detail of the parameters in the
points which follow). Note on GW4060 series: a short press on the button Drying + has
the same meaning of the short press on button Functions.
Selection buttons - Modification of the selected parameter
During modification, the parameter concerned flashes on the display.
Start/Stop – hold down to confirm the modification.
Once the modification has been confirmed the parameter stops flashing and appears
on the display with steady light.
Door opening – hold down to quit the screen for display/modification of the current
parameter.
fig. 25 – Steps for display and modification of the Set and Cloc parameters:
Access the parameter: by pressing the Start/Stop button
Quit the parameter: by pressing the Door opening button.