Electrical System Requirements - Smeg GW1160 User Manual

Glassware washer
Hide thumbs Also See for GW1160:
Table of Contents

Advertisement

13 ELECTRICAL SYSTEM REQUIREMENTS

WARNING
The electrical system to which the appliance is connected must comply with the relevant
regulations (CEI 64-8
WARNING
All electrical checks and system installation must be carried out to the proper standard by skilled
staff with proven experience, qualified to work on electrical systems.
The skilled staff are responsible for ensuring that the ground connection is in good working
order.
For any spare parts: use only genuine Smeg parts, ordering them from your service centre.
Appliances are built for connection to the electrical mains with the following voltages (depending on the chosen
model).
FAMILY
GW1160
GW4060
Characteristics of the power supply cable supplied with the appliance:
-
FROR 5 x 2.5 mm
FROR 4 x 2.5 mm
-
FROR 3 x 2.5 mm
-
The device is supplied without a plug, with a cable with insulated wire terminals.
The device's electrical connection must be made by means of an industrial plug.
The plug must be supplied and fitted by the user. The plug must be of suitable size for the electrical cable and the
electrical rating of the device.
CIRCUIT-BREAKER
A CIRCUIT-BREAKER must be installed for each appliance.
Circuit-breaker characteristics
The appliance is fitted with overcurrent protection devices.
However, a protective device specifically for the appliance (e.g. magnetothermal breaker or fuse
on every phase, suitably rated for the electrical data stated above) should be installed in the
room's electrical panel.
3
CEI 64-8: " "Electrical system users of nominal voltage not exceeding 1000 VAC and 1500 VDC." , Part 7: Special applications and environments.
http://www.ceiweb.it/
User Manual
3
).
VARIANT
CONNECTION
(suffix to the model
DESCRIPTION
name)
STANDARD
400 V three-
(e.g."GW4060"
phase
without numerical
suffix)
230V three
-3
phase without
(e.g.GW4060-3)
neutral
230V single-
-1
phase
(e.g. GW4060-1)
2
(5G2.5), 450/750 V, IMQ mark (three-phase version)
2
(4G2.5), 450/750 V, IMQ mark (three-phase without neutral version)
2
(3G2.5), 450/750 V, IMQ mark (single-phase version)
a. Omnipolar: must break all live conductors;
b. Easily accessible to the user;
c. Easily operated (no tool must be required);
d. Located in close proximity to the appliance;
e. Clearly marked as the appliance circuit-breaker.
GW1160 - GW4060 Series
ELECTRICITY SUPPLY
400V 3N~ / PE / 50Hz / 12A /
7000W
230V 3~ / PE / 50Hz / 19A /
7000W
230V 1N~ / PE / 50Hz / 12A /
2800W
PROTECTIVE DEVICES
INCORPORATED IN THE
APPLIANCE
FUSES 10.3x38 16 A ON
POWER SUPPLY
[L1, L2, L3]
FUSES 10.3x38 20 A ON
POWER SUPPLY
[L1, L2, L3]
FUSES 10.3x38 16 A ON
POWER SUPPLY
[L1, N]
Page 68 - 75