Putting The Engine Into Operation After Scheduled Out-Of-Service-Period - MTU 12 V 4000 M33F Operating Instructions Manual

Table of Contents

Advertisement

3.3 Putting the engine into operation after scheduled out-of-
service-period
Preconditions
☑Engine is stopped and starting disabled.
Putting into operation
Item
Lube oil system
Coolant system
Coolant system
Fuel prefilter
Engine control system
ECU
EIM
EMU
78 | Operation | MS150069/02E 2014-03
Task
Check engine oil level (→ Page 213);
Preheat engine oil if required.
Check coolant level (→ Page 229).
Preheat coolant with preheating unit.
Drain (→ Page 193);
Check that suction-side pressure indicated at the fuel prefilter pressure
gauge is within the limit (→ Page 192).
Refer to automation system operating instructions.
Check plug connections (→ Page 263).
Check plug connections (→ Page 265).
Check plug connections (→ Page 264).

Hide quick links: