MTU 12 V 4000 M33F Operating Instructions Manual page 125

Table of Contents

Advertisement

309 – AL Timing Cylinder A9
Time-of-flight measuring fault of injector
Cause
Flight time value extremely low
or extremely high.
310 – AL Timing Cylinder A10
Time-of-flight measuring fault of injector
Cause
Flight time value extremely low
or extremely high.
311 – AL Timing Cylinder B1
Time-of-flight measuring fault of injector
Cause
Flight time value extremely low
or extremely high.
312 – AL Timing Cylinder B2
Time-of-flight measuring fault of injector
Cause
Flight time value extremely low
or extremely high.
313 – AL Timing Cylinder B3
Time-of-flight measuring fault of injector
Cause
Flight time value extremely low
or extremely high.
314 – AL Timing Cylinder B4
Time-of-flight measuring fault of injector
Cause
Flight time value extremely low
or extremely high.
ZKP-Number: 1.8004.508
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 181).
ZKP-Number: 1.8004.509
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 181).
ZKP-Number: 1.8004.510
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 181).
ZKP-Number: 1.8004.511
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 181).
ZKP-Number: 1.8004.512
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 181).
ZKP-Number: 1.8004.513
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 181).
MS150069/02E 2014-03 | Troubleshooting | 125