MTU 12 V 4000 M33F Operating Instructions Manual page 56

Table of Contents

Advertisement

Inlet valves per cylinder
Exhaust valves per cylinder
RAW WATER CIRCUIT (open circuit)
Raw water pump: Inlet pressure, min.
Raw water pump: inlet pressure, max.
Pressure loss in engine-external raw water
system, max.
LUBE OIL SYSTEM
Lube oil operating temperature before en-
gine, from
Lube-oil operating temperature before en-
gine, to
Lube oil operating pressure upstream of
engine, from
Lube-oil operating pressure before engine,
to
Lube oil operating pressure (low idle)
(meas. point: before engine)
FUEL SYSTEM
Fuel pressure at engine inlet connection,
min. (when engine is starting)
Fuel pressure at supply connection to en-
gine, min. (when engine is running),
Fuel pressure at supply connection to en-
gine (when engine is starting), max.
Fuel supply flow, max.
GENERAL OPERATING DATA
Firing speed, from
Firing speed, to
56 | Product Summary | MS150069/02E 2014-03
Heat exchanger
installed
2
2
Heat exchanger
installed
L
bar
-0.4
L
bar
1.0
L
bar
N
Heat exchanger
installed
R
°C
82
R
°C
90
R
bar
5.0
R
bar
6.0
R
bar
Heat exchanger
installed
L
bar
-0.1
L
bar
-0.3
L
bar
1.5
A
Liters/
min
Heat exchanger
installed
R
rpm
80
R
rpm
120
Heat exchanger
separate
2
2
2
2
Heat exchanger
separate
-0.4
--
1.0
--
N
--
Heat exchanger
separate
82
82
82
90
90
90
5.0
5.0
5.0
6.0
6.0
6.0
Heat exchanger
separate
-0.1
-0.1
-0.1
-0.3
-0.3
-0.3
1.5
1.5
1.5
Heat exchanger
separate
80
80
80
120
120
120
2
2
--
--
--

Hide quick links: