MTU 12 V 4000 M33F Operating Instructions Manual page 124

Table of Contents

Advertisement

303 – AL Timing Cylinder A3
Time-of-flight measuring fault of injector
Cause
Flight time value extremely low
or extremely high.
304 – AL Timing Cylinder A4
Time-of-flight measuring fault of injector
Cause
Flight time value extremely low
or extremely high.
305 – AL Timing Cylinder A5
Time-of-flight measuring fault of injector
Cause
Flight time value extremely low
or extremely high.
306 – AL Timing Cylinder A6
Time-of-flight measuring fault of injector
Cause
Flight time value extremely low
or extremely high.
307 – AL Timing Cylinder A7
Time-of-flight measuring fault of injector
Cause
Flight time value extremely low
or extremely high.
308 – AL Timing Cylinder A8
Time-of-flight measuring fault of injector
Cause
Flight time value extremely low
or extremely high.
124 | Troubleshooting | MS150069/02E 2014-03
ZKP-Number: 1.8004.502
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 181).
ZKP-Number: 1.8004.503
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 181).
ZKP-Number: 1.8004.504
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 181).
ZKP-Number: 1.8004.505
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 181).
ZKP-Number: 1.8004.506
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 181).
ZKP-Number: 1.8004.507
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 181).

Hide quick links: