315 – AL Timing Cylinder B5
Time-of-flight measuring fault of injector
Cause
Flight time value extremely low
or extremely high.
316 – AL Timing Cylinder B6
Time-of-flight measuring fault of injector
Cause
Flight time value extremely low
or extremely high.
317 – AL Timing Cylinder B7
Time-of-flight measuring fault of injector
Cause
Flight time value extremely low
or extremely high.
318 – AL Timing Cylinder B8
Time-of-flight measuring fault of injector
Cause
Flight time value extremely low
or extremely high.
319 – AL Timing Cylinder B9
Time-of-flight measuring fault of injector
Cause
Flight time value extremely low
or extremely high.
320 – AL Timing Cylinder B10
Time-of-flight measuring fault of injector
Cause
Flight time value extremely low
or extremely high.
126 | Troubleshooting | MS150069/02E 2014-03
ZKP-Number: 1.8004.514
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 181).
ZKP-Number: 1.8004.515
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 181).
ZKP-Number: 1.8004.516
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 181).
ZKP-Number: 1.8004.517
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 181).
ZKP-Number: 1.8004.518
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 181).
ZKP-Number: 1.8004.519
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 181).

Hide quick links: