Power source Master MLS™ 3500, Master MLS™ 3503
Mains voltage
Rated power
40% ED MMA
60% ED MMA
100% ED MMA
30% ED TIG
60% ED TIG
100% ED TIG
Connection cable/fuse
Welding current range
Max. welding voltage
Electrode sizes to be
welded
Open circuit voltage
Welding current
control
Efficiency
Power factor
Open circuit power
External dimensions
Weight
22 – MASTER MLS™ 2500, 2503, 3500, 3503, MASTERTIG MLS™ 3000, 3003, 4000, 4003 / 0606
3~400V –15%...+20%
3~230V –15%...+15%
350A
285A
220A
400A
320A
270A
4 x 2.5S mm2 – 5m/16 A delayed
4 x 6S mm2 – 5m/32 A delayed
MMA
TIG
length
width
height
Master MLS™ 3500
Master MLS™ 3503
15kVA
11,3kVA
8kVA
13,8kVA
9,4kVA
7,3kVA
Master MLS™ 3500
Master MLS™ 3503
10 A/20,5V...350A/34,0V
5 A/10,0V...400A/26,0V
45V / 350 A
Ø1,5...6,0 mm
80 V
stepless
86 %
0,95 (350A/34,0 V)
approx. 10W
500 mm
180 mm
390 mm
21 kg