Kemppi Master MLS 2500 Operation Instructions Manual page 11

Hide thumbs Also See for Master MLS 2500:
Table of Contents

Advertisement

3.2.2.4. TIG welding panel MTL – basic functions
5
9
4
7
2
1
1. Selection of MMA welding
2. Selection of arc force (MMA) and pedal low/high (minimum and maximum welding current)
displays and regulation (TIG welding)
3. Selection of hot start (MMA) and gas test (TIG welding)
4. Selection of TIG welding, 4T and 2T functions of torch switch
5. Selection of HF/contact and water fill function
6. Selection of panel, foot pedal and remote control
7. Selection of welding parameters
8. Adjustment of welding parameters
9. Pre-gas 0 - 10 s
10. Upslope 0 - 10 s
11. Welding current
12. Downslope 0 - 15 s
13. Post-gas 1 - 30 s
14. Return to welding current
© KEMPPI OY
MASTER MLS™ 2500, 2503, 3500, 3503, MASTERTIG MLS™ 3000, 3003, 4000, 4003 / 0606– 11
10
11
3
12
13
14
8
6