Error/Warning Indications; Error Indications; Warning Indications - Sony PMW-EX1R Operating Instructions Manual

Solid-state memory camcorder
Hide thumbs Also See for PMW-EX1R:
Table of Contents

Advertisement

Error/Warning Indications

The camcorder informs you of situations where
warning, caution, or an operation check is
required, through messages on the LCD monitor/
EVF screen, the tally lamps, and a buzzer.

Error Indications

The camcorder stops operation after the following indications.
Error indication on
Buzzer
LCD/EVF
E + Error code
Continuous

Warning Indications

When one of the following indications is generated, follow the message to clear the problem.
Warning indication
Buzzer
on LCD/EVF
Media Near Full
Intermittent
Media Full
Continuous
Battery Near End
Intermittent
Battery End
Continuous
Temperature High
Intermittent
Voltage Low
Intermittent
Insufficient Voltage
Continuous
Battery Error
Please Change Battery.
The buzzer is output to the built-in speaker or to
the headphones connected via the headphone
connector. The buzzer volume can be adjusted
with "Alarm Level" in "Audio Output" of the
AUDIO SET menu.
Tally
Cause and measures
lamps
Rapidly
The camcorder may be defective. Recording stops even if
zREC is displayed on the LCD monitor/EVF screen.
flashing
Turn off the power and check the connected equipment, cables,
and media. If they are not defective, turn on the power again. If
the error persists, consult Sony service personnel.
(If power cannot be turned off by setting the power switch to
OFF, remove both the battery pack and the DC IN source.)
Tally
Cause and measures
lamps
Flashing
Free space on the SxS memory card has become insufficient.
Replace it with another at the earliest opportunity.
Rapidly
No space is left on the SxS memory card. Recording, clip
flashing
copying and clip division cannot be performed.
Replace it with another.
Flashing
The battery power will be exhausted soon.
Charge the battery pack at the earliest opportunity.
Rapidly
The battery pack is exhausted. Recording cannot be
flashing
performed.
Connect a power source via the DC IN connector or stop
operation to charge the battery pack.
Flashing
The internal temperature has risen above a safe operation
limit.
Suspend operation, turn off the power, and wait until the
temperature falls.
Flashing
The DC IN voltage has become low (stage 1).
Check the power supply.
Rapidly
The DC IN voltage is too low (stage 2). Recording cannot be
flashing
performed.
Connect other power source.
An error was detected with the battery pack.
Replace the battery pack with a normal one.
Error/Warning Indications
161

Advertisement

Table of Contents
loading

Table of Contents