Error/Warning Indications

The camcorder informs you of situations where warning, caution, or an operation check is required,
through messages on the viewfinder screen, the REC lamp, and a buzzer.
The buzzer is output to the built-in speaker or to the headphones connected via the headphone connector.
When the camcorder is turned on, the message for prompting the APR function appears on the viewfinder
screen if the auto adjustment for the image sensor (APR) has not performed for a period of time. In this
case, perform "APR" (page 90) by following the displayed message.

Error Indications

The camcorder stops operation after the following indications.
Error indication on
LCD/viewfinder
E + Error code

Warning Indications

When one of the following indications is generated, follow the message to resolve the problem.
Warning indication
on LCD/viewfinder
Media Near Full
Media Full
Battery Near End
Battery End
Temperature High
Voltage Low
Insufficient Voltage
EXT. I/F Signal Error
112
Error/Warning Indications
Buzzer
REC
lamp
Continuous
Rapidly
flashing
Buzzer
REC
lamp
Intermittent
Flashing
Continuous
Rapidly
flashing
Intermittent
Flashing
Continuous
Rapidly
flashing
Intermittent
Flashing
Intermittent
Flashing
Continuous
Rapidly
flashing
Cause and measures
The camcorder may be defective. Recording stops even if
zREC is displayed on the viewfinder screen.
Turn off the power and check the connected equipment, cables,
and media. If they are not defective, turn on the power again. If
the error persists, consult Sony service personnel.
(If power cannot be turned off by setting the power switch to
OFF, remove both the battery pack or the DC IN source.)
Cause and measures
Free space on the SxS memory card has become insufficient.
Replace it with another at the earliest opportunity.
No space is left on the SxS memory card. Recording, clip
copying and clip division cannot be performed.
Replace it with another.
The battery power will be discharged soon.
Charge the battery pack at the earliest opportunity.
The battery pack is discharged. Recording cannot be
performed.
Stop operation and change the battery pack.
The internal temperature has risen above a safe operation
limit.
Suspend operation, turn off the power, and wait until the
temperature falls.
The DC IN voltage has become low (stage 1).
Check the power supply.
The DC IN voltage is too low (stage 2). Recording cannot be
performed.
Connect another power source.
An error was detected with the signal in the mounting terminal
for an expansion unit.
Check the connection to the AXS-R5, etc.