Function Tests - Skyjack SJ 3219 Operating Manual

Compact & conventional series (ce)
Hide thumbs Also See for SJ 3219:
Table of Contents

Advertisement

Section 2 - Operation
Conventional
(Back View)
Lower/
Neutral/Raise
Switch
Emergency Stop
Button

2.9 Function Tests

Function tests are designed to discover any malfunctions
before aerial platform is put into service. The operator
must understand and follow step-by-step instructions
to test all aerial platform functions.
wARNiNG
Never use a malfunctioning aerial
platform. If malfunctions are discovered,
aerial platform must be tagged and
placed out of service. Repairs to aerial
platform may only be made by a qualified
service technician.
After repairs are completed, operator must perform a
pre-operation inspection and a series of function tests
again before putting aerial platform into service.
Prior to performing function tests, be sure to read and
understand
Section 2.10
2.9-1 Test Main Power Disconnect Switch
1. At rear of the base, turn main power disconnect
switch to "
" off position.
Result: Aerial platform functions should not
operate.
SJIII Compacts & Conventionals
Free-wheeling
Valve
CAUTION
A
106515AC
Off/Platform/Base Switch
- Start Operation.
December 2007
Lower/
Neutral/Raise
Switch
2.9-2 Base Control Console
Ensure that you maintain three points of
contact when using the ladder to mount/
dismount platform.
1. Use the ladder of aerial platform to access
platform.
2. Close the gate.
3. On platform control console, pull out "
emergency stop button.
4. Use the ladder to dismount from platform.
5. Turn main power disconnect switch to " " on
position.
Function Tests
Compact
(Back View)
Emergency Stop
Button
wARNiNG