Temperature indication Display
With the system in the "OFF" position, press the Thermostat Key and the
Mode Key at the same time. Look at the LCD screen on the transmitter to
verify that a C or F is visible to the right of the Room Temperature display.
(Fig. 3 & 4)
Turn on the Appliance
First close the main ON/OFF switch on the wirings. With the system OFF,
press the ON/OFF Key on the Transmitter. The Transmitter display will show
Figure 3: Display in Fahrenheit
all active Icons on the screen. At the same time IFC will be commanded to
start the ignition process. Once the pilot flame is proven the IFC board will
open the main valve outlet and the appliance main burner will also ignite. A
single "beep" from the IFC module will confirm reception of the command.
Turn off the Appliance
With the system ON, press the ON/OFF Key on the Transmitter. The
Transmitter LCD display will only show the room temperature. At the same
time the IFC will be commanded to turn off the burner. Depending on the
system mode (IPI or CPI) the pilot may shut off (IPI) or remain lit (CPI) and
Figure 4: Display in Celsius
the appliance burner turns OFF. A single "beep" from the Receiver confirms
reception of the command.
Manual Bypass of the Remote System
If the batteries of the receiver or transmitter are low or depleted, the
appliance can be turned off manually using switch located on battery box.
This will bypass the remote control feature of the system.
Key Lock
This function will lock the keys to avoid unsupervised operation.
To activate this function, press the MODE and UP keys at the same time
(fig.5).
To de-activate this function, press the MODE and UP keys at the same time.
Figure 5