29.4.4 DHW quick heat-up

Setting range: Off, On
Factory setting: Off
If this parameter is set, the DHW temperature is controlled once to the set value using all available heat sources. The parameter
is then automatically reset.
Main menu
Main menu
← back
Displays
Default settings
Contractor
← back
29.4.5 Energy saving mode
No function

29.4.6 Active cooling

Setting range: Off, On
Factory setting: Off
Enables the user to activate/deactivate active cooling.
This requires that the system is configured with active cooling and that active cooling is enabled via contractor parameter
WP058 (factory setting: Off).
During active cooling, the cooling capacity of the heat pump is transferred to the heating system.