Specification - Wolf BWL-1 S Installation And Operating Instructions Manual

Split air/water heat pump
Table of Contents

Advertisement

TYPE
Width x height x depth of outdoor unit
(incl. feet, incl. front doors)
Width x height x depth of indoor unit
(incl. feet, incl. front doors)
Weight of outdoor unit
Weight of indoor unit
Refrigerant circuit
Refrigerant type / charge weight
Max. length of refrigerant line
Quantity of refrigerant to be added,
line length >12 m - 25 m
Refrigerant oil
Refrigerant oil charge weight
Compressor type
Maximum operating pressure
Heating output / COP to EN14511
A2/W35 rated output
A7/W35 rated output
A-7/W35 max. output
Output range at A2/W35
Cooling capacity / EER to EN14511
A35/W7 rated output
A35/W18 rated output
Compressor output range for A35/W18
Sound, outdoor unit
Sound power level (based on EN 12102/EN ISO 9614-2)
for A7/W55 at rated heating output
Average sound pressure level at 1 m distance
Application limits
Temperature, operating limits, heating mode
Temperature, operating limits, cooling mode
Maximum heating water temperature
with electric booster heater
Temperature, operating limits, air, heating mode, min/max
Temperature, operating limits, air, cooling mode, min/max
Heating water
Minimum flow rate
Water flow rate, nominal (5K)
Water flow rate, maximum (4K)
Heat pump pressure drop
at nominal water flow rate
Residual head at nominal water flow rate
Maximum operating pressure
Heat source
Air flow rate at nominal operating point
Connections
Connection, heating flow / return /
DHW flow
Connection, refrigerant lines
Dimensions, refrigerant lines
Dimensions, condensate line, outdoor unit
Electrics, outdoor unit
Power supply / fuse protection, outdoor unit
Max. fan power consumption
Power consumption, standby
Max. compressor power consumption
within application limits
Max. compressor current within application limits
Compressor start-up current
Compressor start-up current with blocked rotor
Starting current (charging of DC capacitors)
IP rating, outdoor unit
Maximum number of compressor starts per hour
Electrics, indoor unit
Power supply / fuse connection, heating element
Power supply / fuse protection, control voltage
Power consumption, electric heating
Power consumption, pump
Power consumption, standby
Maximum power consumption, electric heating 6 kW
Maximum power consumption, electric heating 9 kW
IP rating, indoor unit
Provisional data
1)
2)
To ensure the heat pump operates with optimum energy efficiency, the flow rate should not fall below the nominal air flow rate
Available as an accessory for the BWL-1SB
3)
3064298_201507

50. Specification

mm
mm
kg
kg
- / kg
m
g/m
ml
bar
1)
kW / -
kW / -
kW / -
kW
1)
kW / -
kW / -
kW / -
dB(A)
dB(A)
°C
°C
°C
°C
°C
l / min
l / min
l / min
mbar
mbar
bar
m³ / h
2)
UNF
mm
mm
W
W
kW
A
A
A
A
1/h
3)
kW
3)
W
W
A
3)
A
3)
BWL-1S(B) - 07/230 V
BWL-1S(B) - 10/400 V
1040 x 865 x 340
900 x1255 x 340
440 x 790 x 340
440 x 790 x 340
66
31
R410A / 2.15
FV68S
650
Rotating piston
Twin rotating piston
5.1 / 3.3
6.8 / 4.3
6.1 / 2.5
1.9 - 8.8
6.8 / 2.7
8.6 / 3.3
2.9 - 9.6
61
55
+20 to +55
+7 to +20
75
-15 / +35
+10 / +45
15
19.7
24.7
78
490
2600
1~NPE, 230VAC, 50Hz
3~NPE, 400VAC, 50Hz
/ 20A(C)
57
9
3.6
16
15
25
35
Either 3~PE, 400VAC, 50Hz / 16A(B) or
1~NPE, 230 V AC, 50 Hz / 32 A(B)
1~NPE, 230 V AC, 50 Hz / 16 A(B)
2 / 4 / 6 or 3 / 6 / 9
3 - 45
8.7 (400 V AC) / 26.1 (230 V AC)
BWL-1S(B) - 14/400 V
900 x1255 x 340
440 x 790 x 340
110
33
R410A / 2.95
R410A / 2.95
25
60
POE
POE
1100
1100
Twin rotating piston
43
7.6 / 3.8
8.8 / 3.8
10.2 / 4.8
12.1 / 4.8
9.2 / 2.9
10.3 / 2.8
2.9 - 10.6
3.1 - 12.4
8.8 / 2.7
10.7 / 2.5
8.7 / 4.1
12.0 / 3.4
3.1 - 11.0
3.2 - 13.2
60
54
+20 to +55
+20 to +55
+7 to +20
+7 to +20
75
-20 / +35
-20 / +35
+10 / +45
+10 / +45
21
28.8
36
121
550
3
3500
4200
28x1
5/8 + 7/8
10x1 + 16x1
16
3~NPE, 400VAC, 50Hz
/ 20A(C)
/ 20A(C)
70
21
5
8
10
16
30
IP 24
3
3 - 75
3 - 75
5
13 (400VAC)
IP 20
110
35
61
55
75
25
34.1
42.7
141
460
102
21
6.3
10
10
16
30
99