Overview Of Contractor Parameters - Wolf BWL-1 S Installation And Operating Instructions Manual

Split air/water heat pump
Table of Contents

Advertisement

31.3.1 Overview of contractor parameters for split heat pump:
Contractor
Meaning
parameter
System
WP001
System configuration
WP002
Function input 1 (E1)
WP003
Function output 1 (A1)*
Heating HTG
WP010
Set spread / offset
WP011
Heating hysteresis
WP012
ZHP run-on
WP013
Delay for heating by add. ht generator, heating
WP014
HCP run-on
WP015
HC pump rate, maximum
WP016
Enabling spread control
WP017
Max. boiler temp. HTG TV-max
WP018
Min. boiler temp. BWT-min
Domestic hot water DHW
WP020
Cylinder hysteresis
WP021
Enable max. cylinder heating time
WP022
Max. cylinder heating time
WP023
Delay for heating by add. ht generator, DHW
WP024
Minimum DHW temperature
Smart grid
WP025
Smart grid
WP026
External raising, HTG
WP027
External raising, DHW
WP028
External activation
WP031
BUS address
Active cooling
WP053
Outside temp. enable cooling
WP054
Min. flow temp. for cooling
WP055
Offset set flow temp, cooling
WP058
Enable active cooling
(continued on next page)
60
31. Contractor level
01, 02, 05, 11, 12, 14,
15, 33, 34, 51, 52
Compressor ON
0 min ... 30 min
1 min ... 180 min
0 min ... 30 min
40.0 ... 70.0 °C
10.0 ... 40.0 °C
30 min ... 240 min
1 min ... 180 min
10.0 °C ... 55.0 °C
Off, On
0.0 - 20.0 °C
0.0 - 20.0 °C
Off, heat pump, heat
pump and electric
heating
1, 2, 3, 4, 5
15.0 ... 40.0 °C
5.0 ... 25.0 °C
5.0 ... 20.0 °C
Off, On
Setting range
Factory setting Individual setting
none
RT
DHW
RT/DHW
Zirkomat
TPW / Max Th
none
Timer20
Timer50
Timer100
Alarm
Zirkomat
Defrost
Add ht gn
0.0 ... 10.0 °C
5.0 °C
0.5 ... 3.0 °C
2.0 °C
1 min
60 min
5 min
70 % ... 100 %
100 %
Off, On
55 °C
20 °C
1.0 ... 10.0 °C
2.0 °C
Off, On
120 min
60 min
45.0 °C
0.0 °C
0.0 °C
25.0 °C
20.0 °C
15.0 °C
01
none
none
On
ON
Off
Off
1
Off
3064298_201507