7-2 POWER UNIT

POWER UNIT

REMOVAL

Before removing power unit :
• Drain engin oil.
• Disconnect battery cable from battery.
• Remove both side lower covers. (see page.8-2)
[ Manual start model ]
• Remove recoil starter. (see page 6-2)
[ Electric start model ]
• Remove Flywheel cover.
Remove the eight (8) cylinder head cover bolts, and then cylin-
derhead cover 1 and breather hose 2 .
[ Tiller handle model ]
• Remove throttle cables 3 from throttle drum 4 .
• Remove bolt 5 , throttle drum 4, throttle cam link rod6 and
throttle limiter rod 7 .
• Remove shift lever link rod 8 .