Disabling The Overnight Shutdown - SMA SUNNY BEAM User Manual

With bluetooth wireless technology
Hide thumbs Also See for SUNNY BEAM:
Table of Contents

Advertisement

SMA Solar Technology AG
6.9.3 Disabling the Overnight Shutdown
As the default setting, the Sunny Beam data query from inverters is shut down over night, because the
inverters do not supply at night and therefore do not generate any data. Only disable the Overnight
Shutdown if you are using a Windy Boy (wind inverter SMA Solar Technology).
1. Select "Settings > Data query > Overnight Shutdown".
2. Remove the check mark from the "active" box.
☑ The Overnight Shutdown is now disabled.
To prevent the batteries from discharging when the overnight shutdown is disabled, connect the Sunny
Beam to the computer using the USB connection cable supplied with the Sunny Beam. The computer
will supply the batteries with power. The computer needs to remain switched on.
Alternatively, you can connect the Sunny Beam to the USB plug-in power supply, which supplies the
batteries with power via a socket. The USB plug-in power supply is not included in the scope of
delivery. You can order the plug-in power supply as an accessory from SMA Solar Technology, see
Chapter 13 "Accessories" (page 83).
User Manual
BeamBT-BEN091910
Operation
51