Error Code
Message Information
Action
TMP0118
Message
LCD Message
Details
Action
TMP0119
Message
LCD Message
Details
Action
TMP0120
Message
LCD Message
Details
Action
TMP0121
Message
LCD Message
Details
Action
VLT0204
Message
LCD Message
Details
154
Re-configure system to the minimum supported configuration. If
issues persists, contact support.
The system inlet temperature is less than the lower warning
threshold.
System inlet temperature is outside of range.
Ambient air temperature is too cool.
Check the system operating environment.
The system inlet temperature is less than the lower critical threshold.
System inlet temperature is outside of range.
Ambient air temperature is too cool.
Check the system operating environment.
The system inlet temperature is greater than the upper warning
threshold.
System inlet temperature is outside of range.
Ambient air temperature is too warm or one or more fans may have
failed.
Check the system operating environment and review event log for fan
failures.
The system inlet temperature is greater than the upper critical
threshold.
name > temperature is outside of range. Check Fans.
System inlet <
Ambient air temperature is too warm or one or more fans may have
failed.
Check the system operating environment and review event log for fan
failures.
name > voltage is outside of the allowable range.
The system board <
System board voltage is outside of range.
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.