Pcie Ssd Led Indicators - Dell PowerEdge R920 Owner's Manual

Hide thumbs Also See for PowerEdge R920:
Table of Contents

Advertisement

Drive-Status
Condition
Indicator Pattern
(RAID Only)
Blinks green two
Identifying drive or preparing for removal
times per second
Off
Drive ready for insertion or removal
Blinks green, amber,
Predicted drive failure
and off
Blinks amber four
Drive failed
times per second
Blinks green slowly
Drive rebuilding
Steady green
Drive online
Blinks green three
Rebuild aborted
seconds, amber three
seconds, and off six
seconds

PCIe SSD LED Indicators

Figure 4. PCIe SSD LED Indicators
1.
activity indicator
While the operating system is running, the status indicator provides the current status of the device. The following table
lists the device states along with the associated LED indicator codes.
Table 1. PCIe SSD States and LED Indicator Codes
State Name
Device status off
Device online
NOTE: The drive status indicator remains off until all hard drives are initialized after the
system is turned on. Drives are not ready for insertion or removal during this time.
Slot/Device State
The server or device is not
powered up.
The device is powered up.
2.
status indicator
Status LED (Green)
Off
On
Status LED (Amber)
Off
Off
13

Advertisement

Table of Contents
loading

Table of Contents