Troubleshooting A Storage Controller - Dell PowerEdge R920 Owner's Manual

Hide thumbs Also See for PowerEdge R920:
Table of Contents

Advertisement

a. Restart the system and press <F10> during system startup to run the Lifecycle Controller, and then run the
Hardware Configuration wizard to check the RAID configuration.
See the Lifecycle Controller documentation or online help for information on RAID configuration.
b. Ensure that the hard drive(s) have been configured correctly for the RAID array.
c. If there is a failed or offline hard drive in a redundant array, take the hard drive offline and reseat the drive.
d. Exit the configuration utility and allow the system to boot to the operating system.
3.
Ensure that the required device drivers for your controller card are installed and are configured correctly. See the
operating system documentation for more information.
4.
Restart the system and enter the System Setup.
5.
Verify that the controller is enabled and the drives are displayed in the System Setup.
If the problem persists, try troubleshooting the expansion cards or see

Troubleshooting A Storage Controller

CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
NOTE: When troubleshooting a SAS or PERC controller, see the documentation for your operating system and the
controller.
1.
Run the appropriate diagnostic test. For more information, see
2.
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3.
Open the system.
4.
Verify that the installed expansion cards are compliant with the expansion card installation guidelines.
5.
Ensure that each expansion card is firmly seated in its connector.
6.
Close the system
7.
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
8.
If the problem is not resolved, turn off the system and attached peripherals, and disconnect the system from the
electrical outlet.
9.
Open the system.
10.
Remove all expansion cards installed in the system.
11.
Close the system.
12.
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
13.
Run the appropriate diagnostic test. For more information, see
Getting
Help.
14.
For each expansion card you removed in step 10, perform the following steps:
a.
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
b.
Open the system.
c.
Reinstall one of the expansion cards.
d.
Close the system.
e.
Run the appropriate diagnostic test. For more information, see
If the tests fail, see
Getting
Help.
Getting
Help.
Using System
Diagnostics.
Using System
Diagnostics. If the tests fail, see
Using System
Diagnostics.
123