3.4
REMOVAL & RE-FITTING OF THE GLASS FRAME & PANEL
a)
Remove the "Curve" fascia by unscrewing the retaining screws and
lifting the "Curve" fascia off the brackets, in the reverse order as
detailed in section 3.3, on page 18
b)
The glass frame is then removed by using the 6mm allen key supplied
to unscrew the 4 off allen bolts (Fig. 16) and lifting the glass frame /
panel clear.
Fig. 16
c)
To re-fit the glass panel / frame, re-assemble in reverse order.
d)
Replace the allen key supplied in its location slot at the bottom
right hand side of the combustion chamber.
The ceramic fibre back used in this product is manuafctured from R.C.F
(Refractory Ceramic Fibre) To ensure that the release of fibres from this item
is kept to a minimum, during installation and servicing we recommend that
you use a HEPA filtered vacuum to remove any dust accumulated in and
around the appliance before and after working on the appliance. When
replacing these articles we recommend that the replaced items are not
broken up, but are sealed within heavy duty polythene bags, clearly labelled
as "RCF waste". RCF waste is classed as a "stable", non reactive
hazardous waste and may be disposed of at a landfill licensed to accept
such waste Protective clothing is not required when handling these
articles, but we recommend you follow the normal hygiene rules of not
smoking, eating or drinking in the work area, and always wash your hands
before eating or drinking.
4 off 6mm Glass
Frame Retaining
Allen Bolts