Flavel Curve Installation And Maintenance Instructions Manual page 12

Radiant flame effect gas fire
Table of Contents

Advertisement

Proceed as follows :-
a)
Prepare the mounting holes on the wall to which the fire is to be
fitted. See Fig. 5 below.
Fig. 5
34mm
b)
Centre the closure plate around the fireplace opening and mark the
positions of the mounting holes as shown above in fig. 5
c)
Remove the closure plate and drill suitable holes to suit the method of
fixing to the wall.
Please Note : Due to the varying wall conditions encountered, fixings
are not supplied with the product.
d)
Decide which side the gas supply is to enter the fire from. If concealed
pipe work is required plan the pipe run to enter from behind the
closure plate. This will require a cut out in the closure plate itself, or a
suitable hole creating in the plasterboard / brickwork below the edge of
the fire. See Fig. 6 overpage for diagram to relate the position of the
gas inlet / restrictor elbow to the closure plate supplied. The gas
connection to the appliance should be made to the isolating / inlet elbow
using 8mm rigid tubing.
e)
Re-position closure plate and seal to the wall with suitable tape.
f)
The combustion chamber can then be mounted to the wall via the holes
as detailed in section c).
550mm CRS
Spigot
Mounting holes for combustion chamber
Fire Opening
C/L
12
Diameter
6mm
Closure Plate

Hide quick links: