Initialization Of B Page Data - Sony Digital8 DCR-TRV410 Service Manual

Digital video camera recorder
Table of Contents

Advertisement

Address
Initial
value
NTSC
PAL
81
7B
7B
White balance adj. (LCD)
82
80
80
D range adj. (LCD)
83
89
89
V-COM level adj. (LCD)
84
80
80
VCO adj. (LCD)
85
80
80
V-COM adj. (LCD)
86
Fixed data-1
87
88
89
8A
84
84
Bright adj. (LCD)
8B
78
78
Color adj. (LCD)
8C
8D
8D
Contrast adj. (LCD)
8D
Fixed data-1
8E
(Initialized data)
8F
Table. 5-1-3.
Remark
5-12

1-2-3. INITIALIZATION OF B PAGE DATA

(DCR-TRV510/TRV510E)
1. Initializing the B Page Data
Note: If the B page data has been initialized, "Modification of B Page
Data" need to be performed again.
Adjusting page
B
Adjusting Address
00 to 7F
Switch setting:
1) POWER .................................................................. CAMERA
2) LOCK/STANDBY/MEMORY ............................. MEMORY
Initializing Method:
1) Select page: 0, address: 01, and set data: 80.
2) Select page: 5, address: 02, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 5, address: 01, set data: F3, and press the PAUSE
button.
4) Select page: 5, address: 00, set data: 01, and press the PAUSE
button.
5) Select page: 5, address: 01, and wait for several seconds.
6) Select page: 5, address: 00, and check that the data changes to
"00".
7) Select page: 5, address: 02, and check that the data changes to
"00".
8) Perform "Modification of B Page Data".
2. Modification of B Page Data
If the B page data has been initialized, change the data of the "Fixed
data-2" address shown in the following table by manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 80.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note : If copy the data built in the different model, the camcorder
may not operate.
3) When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of B Page data
1) Select page: 2, address: 00, and set data: 29.
2) Select page: 2, address: 01, and set data: 29, and press the
PAUSE button of the adjusting remote commander.
3. B Page Table
Note: Fixed data-1 : Initialized data. (Refer to "1. Initializing the B Page
Data".)
Fixed data-2 : Modified data. (Refer to "2. Modification of B Page
Data".)
Address
Remark
00
Fixed data-1
01
(Initialized data)
02
03
04
05

Hide quick links: