Sony Digital8 DCR-TRV410 Service Manual page 109

Digital video camera recorder
Table of Contents

Advertisement

Address
Remark
74
Fixed data-1
75
(Initialized data)
76
77
78
79
7A
7B
7C
7D
7E
7F to FF
Table. 5-1-4.
1-2-4. INITIALIZATION OF E, F PAGE DATA
1. Initializing the E, F Page Data
Note: If the E, F page data has been initialized, "Modification of E, F
Page Data" and following adjustments need to be performed again.
1) Camera system adjustments
2) "Hi8/standard 8 mm switching position adjustment" and "CAP
FG offset adjustment" of the servo & RF system adjustments
3) Video system adjustments
4) IR transmitter adjustments
5) Audio system adjustments
Adjusting Page
Adjusting Address
Adjusting Page
Adjusting Address
Initializing Method:
1) Select page: 0, address: 01, and set data: 80.
2) Select page: 6, address: 00, and set data: 55 (NTSC) or data:
51 (PAL).
3) Select page: 6, address: 01, set data: 55 (NTSC) or data: 51
(PAL), and press the PAUSE button of the adjustment remote
commander.
4) Select page: 6, address: 02, and check that the data is "01".
5) Select page: 0, address: 01, and set data: 00.
6) Perform "Modification of E, F Page Data".
2. Modification of E, F Page Data
If the E, F page data has been initialized, change the data of the
"Fixed data-2" address shown in the following tables by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note : If copy the data built in the different model, the camcorder
may not operate.
3) When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F Page data
1) Select page: 2, address: 00, and set data: 29.
2) Select page: 2, address: 01, and set data: 29, and press the
PAUSE button of the adjustment remote commander.
5-14
F
00 to FF
E
00 to FF