6. Hi8/standard 8mm Switching Position Adjustment
(VC-213 board)
If deviated in this case causes switching noise or jitter on the Hi8/
standard 8mm mode played back screen.
Mode
Playback
Signal
Hi8/standard 8mm alignment tape:
For tracking adjustment
(WR5-1NP(NTSC))
(WR5-1CP(PAL))
CH1: Pin 8 of CN910 (VC RF SWP)
Measurement Point
CH2: Pin 5 of CN910 (PB RF)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
3E, 3F
t1=0 ± 10 µsec
Specified Value
Adjusting Method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 2C, set data: 20, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 2, address: 2E, and set data: 02.
4)
Set to the playback mode.
5)
Select page: F, address: 3E, change the data and minimize “t1”,
and then press the PAUSE button. (Coarse adjustment)
6)
Select page: F, address: 3F, change the data and adjust so that
the switching position (t1) becomes the specified value. (Fine
adjustment)
7)
Press the PAUSE button.
8)
Select page: F, address: 2C, set data: 00, and press the PAUSE
button.
9)
Select page: 2, address: 2E, and set data: 00.
10) Select page: 0, address: 01, and set data: 00.
CH1
CH2
Enlargement
CH1
t1=0 ± 10 µ sec
CH2
Fig. 5-3-7.