6. AGC Gain Calibration Adjustment
Subject
Clear chart
(Color reproduction adjustment frame)
Measurement Point
Display data of page 1 (Note)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
2E, 2F, 30, 31
Specified Value
Data1 : 0196 to 0283
Data2 : 0C97 to 13F4
Note: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Switch setting:
1) NIGHT SHOT .................................................................. OFF
2) DIGITAL ZOOM (Menu display) ................................... OFF
3) STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 6, address: 01, set data: 71, and press the PAUSE
button of the adjustment remote commander.
(The AGC gain calibration adjustment is performed and the
adjustment data is stored in page: F, address: 2E to 31.)
3) Select page: 6, address: 02, and check that the data is "01".
4) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
Checking method:
1) Select page: 0, address: 03, and set data: 25.
2) Select page: 6, address: 9A, and set data: 03.
3) Select page: 6, address: 01, set data: 9B, and press the PAUSE
button.
4) Select page: 6, address: 02, and check that the data is "01".
5) Select page: 1, and check that the display data (Note) satisfies
the specified value of data1.
6) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
7) Select page: 6, address: 9A, and set data: 99.
8) Select page: 6, address: 01, set data: 9B, and press the PAUSE
button.
9) Select page: 6, address: 02, and check that the data is "01".
10) Select page: 1, and check that the display data (Note) satisfies
the specified value of data2.
Processing after Completing Adjustments
1) Select page: 6, address: 01, and set data: 00, and press the
PAUSE button.
2) Select page: 6, address: 9A, and set data: 00.
3) Select page: 0, address: 01, and set data: 00.
4) Select page: 0, address: 03, and set data: 00.
Display data