1-1-2. Preparations
Note 1: For details of how remove the cabinet and boards, refer to "2.
DISASSEMBLY".
Note 2: When performing only the adjustments, the lens block and boards
need not be disassembled.
1)
Connect the equipment for adjustments according to Fig.
5-1-3.
2)
The front panel block (MA-356 board, focus ring, microphone
unit) must be assembled because the focus ring is used for
adjustments.
Note 3: As removing the cabinet (R) (removing the VC-213 board CN911)
means removing the lithium 3V power supply (CF-64 board
BH001), data such as date, time, user-set menus will be lost. After
completing adjustments, reset these data. If the cabinet (R) has
been removed, the self-diagnosis data, data on history of use (total
drum rotation time, etc. ) will be lost. Before removing, note down
the self-diagnosis data and data on history use (data of page: 2,
address: A2 to AA). (Refer to "SELF-DIAGNOSIS FUNCTION"
for the self-diagnosis data, and to "5-4. Service Mode" for the
data on the history use.)
Note 4: Setting the "Forced Camera Power ON" Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the camera power to be turned
on with the front panel block removed. After completing
adjustments, be sure to exit the "Forced Camera Power ON
Mode".
Note 5: Exiting the "Forced Camera Power ON" Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.