Information And Requirements; Appliance Information - Flavel Finesse FSRC**MN Installation, Maintenance & User Instructions

Decorative fuel effect gas fire
Table of Contents

Advertisement

1.0

APPLIANCE INFORMATION

Model
Gas Type
Main injector (1 off)
Burner Type
Max. Gross Heat Input :
Min. Gross Heat Input &
Ignition Rate :
Cold Pressure :
Ignition :
Electrode Spark Gap
Packed Weight (All models)
Fire box Dimensions (with trim fitted)
Width :
(with trim fitted)
Height :
(with trim fitted)
Depth :
(trim only)
Depth :
(firebox only)
Gas Connection :
Appliance Efficiency Declaration
The efficiency of this appliance has been measured as specified in
BS 7977-1 : 2002 and the result is 51%.
The gross calorific value of the fuel has been used for this efficiency
calculation.
The test data from which it has been calculated has been certified by
Advantica. The efficiency value may be used in the UK Government's
Standard Assessment Procedure (SAP) for energy rating of dwellings.
SECTION 1

INFORMATION AND REQUIREMENTS

8mm Compression
FSRC**MN & FSRP**MN
** denotes fascia variant of product
G20
Size 440
Aeromatic Self Vitiating Tubular Burner
6.5 kW
2.2 kW
20.0 +/-1.0 mbar
Push-button Piezo
4.0mm
13.0 kg
560mm
690mm
50mm
125mm
(Supplied with fire)