Gas Tightness And Inlet Pressure - Flavel Finesse FSRC**MN Installation, Maintenance & User Instructions

Decorative fuel effect gas fire
Table of Contents

Advertisement

m)
Before making the final gas connection, thoroughly purge the gas
supply pipework to remove all foreign matter, otherwise serious
damage may be caused to the gas control valve on the fire.
The other firebox fixing method is as follows :-
In installations where the cable method is not suitable (e.g. loose masonary in rear
of fire opening) the firebox can be secured to the fire surround using four screws
and wall plugs provided. Below (fig. 11) is a diagram to indicate the hole centre
positions available on the firebox to facilitate the screw fixing to the fireplace /
surround.
Fig. 11
520mm
2.4

GAS TIGHTNESS AND INLET PRESSURE

a)
Remove the pressure test point screw from the inlet elbow and fit a
manometer.
b)
Turn on the main gas supply and carry out a gas tightness test.
c)
Depress the control knob and turn anti-clockwise to the position marked
ignition / low. Hold in the control knob for a few seconds to purge the
pipe work then press the igniter button. The burner should light,
300mm
430mm
17
Firebox
Mounting
Flange
140mm