2.1
UNPACKING THE FIRE
Carefully lift the fire out of the carton. Remove the loose item packaging carefully
from the front of the appliance. Check the contents as listed :-
Packing Check List - Coal Fuel-bed Models
1off
Fire box / burner assembly
1off
Boxed ceramic base and 7 synthetic coals
1off
Loose items bag.
1off
Fascia
1off
Installation / User book (Combined)
Packing Check List - Pebble Fuelbed Models
1off
Fire box / burner assembly
1off
Boxed ceramic base and 7 synthetic pebbles (4 large, 3 small)
1off
Loose items bag.
1off
Fascia
1off
Installation / User book (Combined)
2.2
INSTALLING THE FIRE BOX
Establish which type of flue you are intending to install the fire in to :-
225 x 225mm (9 inch x 9 inch) brick built chimneys
175mm (7 inch) diameter lined brick or stone flue, or insulated pre-fabricated
metal flue box to B.S. 715.
When installing into 125mm (5 inch) diameter lined brick or stone flue, or
insulated pre-fabricated metal flue box to B.S. 715 and pre-cast flues the
restrictor baffle must not be fitted.
A spillage test must always be carried out to check satisfactory
clearance of flue products, regardless of the type of flue the
appliance is being fitted to.
PLEASE NOTE :- IF INSTALLING THIS PRODUCT INTO A HOLE IN THE WALL
TYPE INSTALLATION IN WHICH THE FLUE TYPE IS PRE-CAST, SPECIALIST
ADVICE MUST BE OBTAINED FROM A STRUCTURAL ENGINEER
REGARDING THE RE-POSITIONING OF THE STARTER BLOCKS.
UNDER NO CIRCUMSTANCES SHOULD THE FIRE BE RECESSED INTO THE
GATHER BLOCK, OFFSET OR STRAIGHT FLUE BLOCKS.
SECTION 2
INSTALLATION OF FIRE
10