Hearths; Spillage Monitoring System - Flavel Finesse FSRC**MN Installation, Maintenance & User Instructions

Decorative fuel effect gas fire
Table of Contents

Advertisement

1.10

HEARTHS

This appliance must only be installed at a minimum height of 225mm above the
floor level, (measured from the bottom edge of the 4 sided trim) e.g. above the
level of the carpet or floor covering.
1.11

SPILLAGE MONITORING SYSTEM

This appliance is fitted with an atmosphere sensing spillage monitoring system in
the form of an oxygen sensing burner. This is designed to shut the fire off in the
event of a partial or complete blockage of the flue causing a build up of
combustion products in the room in which the fire is operated. The following are
important warnings relating to this spillage monitoring system :-
1) The spillage monitoring system must not be adjusted by the installer.
2) The spillage monitoring system must not be put out of operation.
3) When the spillage monitoring system is exchanged only a complete original
manufacturers part may be fitted.
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Finesse fsrp**mn

Table of Contents