Servicing Notes
Servicing should be carried out annually by a competent person such as a CORGI
registered engineer. This is a condition of the Flavel guarantee schemes.
The service should include visually checking the chimney and fire opening for
accumulations of debris and a smoke test to check for a positive up-draught in the
chimney.
The condition of the coals or pebbles should be checked and if necessary the
whole set should be replaced with a genuine replacement set.
The burner assembly is designed to be removed as a complete unit for ease of
access. After any servicing work a gas tightness check must always be
carried out. All sections apply for both coal & pebble fuelbed model
variants.
For Diagrams refer to Section 2
4.1
Removing the burner assembly from the fire.
4.1.1
Prepare work area (lay down dust sheets etc.)
4.1.2
Remove the fascia and put it in a safe location. Remove the loose
coals or pebbles from the fuel bed. Remove the fuelbed matrix.
4.1.3
Isolate the gas supply and remove the inlet pipe from the appliance
inlet elbow. Unscrew and remove the two screws which retain the
burner at the base. Lift the burner retaining tabs from the rear of the
firebox & remove the burner assembly from the fire.
4.1.4
To refit the burner assembly. Push the retaining tabs into the rear panel
of the firebox and secure the burner at the base of the control panel
with two screws. Refit the gas supply pipe and carry out a gas
tightness test. Refit the coals or pebbles referring to section 3 for the
correct layout. The fascia can now be re-positioned.
4.2
Removing the Piezo Igniter
4.2.1
Remove the burner assembly as in section 4.1
4.2.2
Disconnect the ignition lead from the piezo and unscrew the
retaining nut on the rear of the control panel. Withdraw the piezo from
the front of the control panel. Re-assemble in reverse order and carry
out a gas tightness test.