Cornelius Granita Training Manual page 46

Ice peak
Table of Contents

Advertisement

Ice Peak Training Manual
Remove the 2 - 13mm bolts that hold the condenser
fan motor bracket in place and pull the assembly our
of the chassis.
T
R
RANSFORMER
1.
Remove left side panel (see Condenser Filter Replacement, step 1). Remove 22 10mm nut and slip
the transformer off of its mounting stud.
2.
Remove the left side panel (see Condenser Fil-
ter Replacement, step 1) to service fuses.
Publication Number: TP01057
EMOVAL
Transformer
- 38 -
FIGURE 74
Mounting
Stud
Mounting
Washer
Low Voltage
Fuse 10A
High Voltage
Fuses 20A