7.
Unscrew the securing bolt clockwise. Pull off the auger
and remove the shaft seal and the bowl seal.
8.
Remove the drain tray by lifting up on the front edge, while
lowering the rear edge, and then lift it off the unit.
CAUTION: Avoid the use of abrasive cleaners which can
damage the finish. Do not put the parts in a dishwasher.
Dishwasher may damage some parts such as the clear
plastic bowl(s), auger gears, and top mixing bar.
9.
Thoroughly wash each part that has been removed in
steps 1-8 and the condensation tray, as well as the freeze
cylinder with warm water and mild dish washing detergent.
Rinse well with clear water and allow to air dry. Reassem-
ble with clean hands.
10. Reassemble the mixing unit, according to the following procedures (see Figure 6):
• Moisten the bowl seal with water and slip it into place at the back of cylinder with ribs angled
toward back of freezer.
• Apply food grade lubricant to the inside of the shaft seal and place the shaft seal on with the
flared end of seal toward back of freezer.
• Replace the auger assembly on the evaporator.
• Secure all the parts in place by screwing on the securing bolt counterclockwise.
Publication Number: TP01057
Securing
- 16 -
Shaft
Bowl
Seal
Seal
Auger
Bolt
FIGURE 25
Drain
Drainage
Tray
Tube
FIGURE 26
Condensation Tray
Freeze
Cylinder
FIGURE 27
© 2003, IMI Cornelius Inc.