Cornelius Granita Training Manual page 44

Ice peak
Table of Contents

Advertisement

Ice Peak Training Manual
V
S
ISCOSITY
WITCH
1.
Remove the 2 mounting screws and disconnect
the wire connectors to remove the viscosity
switch. Note: When installing the new switch
make sure the wires to the terminal are con-
nected to 1 and 3.
2.
Remove the gear drive motor (Gear Motor
Removal, steps 1-7) before replacing an auger
drive shaft pin. Pull the shaft out of the evapora-
tor assembly.
3.
Remove the gear drive motor (Gear Motor Removal, steps 1-7) before replacing a bowl temperature
sensor.
Publication Number: TP01057
R
EMOVAL
FIGURE 68
Auger Drive
Shaft Shear
Pin
Bowl
Temp
Sensor
- 36 -
Terminal
#2
Mounting
Screws
Terminal
#1
FIGURE 66
FIGURE 67
FIGURE 69
© 2003, IMI Cornelius Inc.