Cornelius Granita Training Manual page 36

Ice peak
Table of Contents

Advertisement

Ice Peak Training Manual
Product is leaking from the dis-
pensing valve
Product is flowing into drain tray
through drainage tube
The auger and/or the upper mix-
ing unit is not turning
The auger and/or the upper mix-
ing units are creating noises as
they rotate
There is no light in the merchan-
dising lid or rear merchandising
panel
The cover does not fit properly on
the bowl
"Filtr" or "Err" message appears
on the touchpad LED readout
Publication Number: TP01057
The dispensing valve has been
incompletely or incorrectly replaced
in its position
The free movement of the dispens-
ing valve is impeded
Dispensing valve o-rings are dam-
aged
The bell shaped "shaft" seal
between the front of the cylinder
and the auger hub has not been
reinstalled properly
The bell shaped "shaft" seal or the
spindle bushing seal is damaged or
worn
Auger not turned on
Some electrical connections are
not complete
The gear motor(s) are malfunction-
ing
The large red bowl seal is not in
position, causing the gear teeth not
to mesh
The product brix is incorrect
The bell shaped "shaft" seal has
been replaced without lubrication
or is damaged
The auger has been incompletely
or incorrectly reassembled (ie the
auger's gear pins are not properly
seated)
The light bulb is burnt out
The 5 Amp fuse between the trans-
former and the lamp is blown
The transformer is blown
The bowl is incorrectly positioned
(the lower, outside corner is not
over the lower, outside base piece)
• The filter is dirty and needs to
be cleaned
• The unit is positioned too close
to a wall or other object restrict-
ing air flow and causing the
machine to run at a higher tem-
perature
• The filter is not properly
installed
• The unit has been installed
near a heat source, such as a
coffee machine, ice maker or
cold beverage machine which
expels hot air from its vents,
causing the machine to run at a
high temperature. (Installation
near a heat source should be
avoid)
- 28 -
Reassemble and replace
Clean and lubricate the valve and
valve cylinder with the lubricant
provided with the machine
Replace the o-rings
Find the seal and put it back in
place
Replace the damaged/worn seal
and check the condition of the
driveshaft.
Turn auger on
Check the contacts and correct the
ones that are incomplete
Replace the gear motor(s)
Check and correct
Check the product brix and correct
Replace or Clean and lubricate
with the lubricant provided with the
machine
Check and correct
Replace (See "Changing the light
bulb" section in this manual)
Replace
Replace
Remove bowl and position properly
• Clean and replace filter follow-
ing instructions (Removing and
Cleaning Filter)
• Reposition unit to maximize
ventilation space (see installa-
tion figures)
• Properly install filter see
"Removing and cleaning filter"
• Reposition unit to maximize
ventilation space (see installa-
tion figures)
© 2003, IMI Cornelius Inc.

Hide quick links:

Advertisement

Table of Contents
loading