6.
Press the "Auto Timer" clock button to set the minutes to complete time setting that you want it to turn
to refrigeration mode, (defrost mode). Then press the "Press To Select Function" button to save the
setting.
7.
Proceed to setting the time you want the machine to turn to freezing mode by following steps 4 above.
Then press the "Press To Select Function" button to save the time settings for freeze mode. Freeze
light should be blinking.
NOTE: Once the settings have been saved, the unit will save the settings, even when the power
switch is turned OFF.
When the light on the "Auto Timer" clock button is ON the defrost timer is activated. To turn OFF the defrost
timer, press the "Auto Timer" clock button(s) until the light(s) on the clock button(s) turns off.
Operate in Automatic Mode (with Defrost Timer Activated)
1.
Turn power switch ON and wait for LED to light up.
2.
Press auger button ON for the side you are setting.
3.
Press the "Auto Timer" button until it is illuminated, to operate in defrost mode.
4.
When setting automatic times, please keep in mind it will take time for the frozen product to become
liquid or vice versa.
"Filter Cleaning" Alarm
A filter cleaning alarm will activate when the unit is running hot due to insufficient internal air circulation.
When this occurs a "Filter" message will appear on the touch pad LED display and an intermittent audible
tone will also sound to alert the operator of this condition.
The "Filter" message will appear when the alarm activates (a beeping sound every 4-5 seconds). To deter-
mine the condition that caused the alarm and correct the problem, see the list of conditions below:
Condition: The filter is dirty and needs to be cleaned.
Corrective Action: Clean or replace filter following instructions (see "removing and cleaning filter").
Condition: The unit is positioned too close to a wall or other object restricting air flow and causing the
machine to run at a high temperature.
Corrective Action: Reposition until to maximize ventilation space (minimum 8" at rear and sides).
Condition: The filter is not properly installed.
Corrective Action: Properly install filter (see "removing and cleaning filter").
Condition: The unit has been i8nstalled near a heat source, such as a coffee machine, ice maker, or
cold beverage machine which expels hot air from its vents, causing the machine to run at a high temper-
ature. (Installation near a heat source should be avoided).
Corrective Action: Reposition unit to maximize ventilation space.
"System Over Temperature" Alarm
A system over temperature alarm will activate as a safety when the unit has overheated to protect the
compressor.
The system automatically goes to OFF status where the compressor's operations is stopped, while
augers will keep working to avoid forming ice blocks.
When this occurs an "Err" message will appear on the touch pad LED readout accompanied by a con-
tinuos buzzer sound to alert the operator of this condition.
When this alarm activates, turn off all switches. Then determine the condition (see "Filter Cleaning"
Alarm section for conditions and corrective actions.
Publication Number: TP01057
- 6 -
© 2003, IMI Cornelius Inc.