Parallel System Balancing; Connect For Balancing; Figure 4.7 - Gain Control Pin Settings; Figure 4.8 - Connecting For Balancing (Four In Parallel Shown) - AE Techron 7000-Series Configuration Manual

Multi-amp systems
Hide thumbs Also See for 7000-Series:
Table of Contents

Advertisement

1.
On the amplifier main board, locate the
connector that connects the external
gain control to the main board by
following the wire leading from the gain
control (see Figure 4.6).
2.
Pull gently upward to remove the 3-pin
connector from the main board. Secure
the gain-control cable within the
amplifier cabinet.
3.
To set a fixed gain of 20, place a shunt
(supplied) across pins 1 and 2 as
shown in Figure 4.7.
4.
If preferred, a fixed gain can be set at
another level; place two resistors (not
supplied) across pins 1 and 2 (resistor
1) and pins 2 and 3 (resistor 2) as
shown in Figure 4.7. Note: these resistors
can be mounted to a header or soldered
directly to the pins.
4.4

Parallel System Balancing

Complete the following procedures to balance
your parallel amplifier system.
ELECTRIC SHOCK HAZARD. Output potentials
from the amplifier can be lethal. Make
connections only with amplifier AC power OFF
and input signals removed.
4.5

Connect for Balancing

1.
For each amplifier in your system, connect a
leg of the black output cable found in the
Parallel Wiring Kit to one of the amplifier's
output connectors labeled COM (7224) or
SAMPLED COMMON (7548/7796) on the
amplifier back panel. Important: Do not
connect this cable to the LOAD and do not
connect the red cable at this time. See
Figure 4.8.
2.
Starting with either end of the DB-25
Interlock cable found in the Parallel Wiring
Kit, connect the DB-25 connector to the
INTERLOCK – I/O CONNECTOR on the SIM-
BNC input card of the first amplifier in your system. Connect additional connectors on the DB-25 cable to
the INTERLOCK – I/O CONNECTOR on the SIM-BNC input card of additional amplifiers in your system.
See Figure 4.8.
97-8002465_06-09-14
7000-SERIES MULTI-AMP CONFIGURATION GUIDE
Figure 4.8 – Connecting for Balancing (Four in Parallel shown)
Information subject to change
Figure 4.7 – Gain Control Pin Settings
19